VolivciA. Johnson & Co London
Volivci
A. Johnson & Co London
Stanje
Rabljeno
Lokacija
Derby 

Prikaži slike
Prikaži karto
Podatki o stroju
Cena in lokacija
- Lokacija:
- Derby, UK

Klic
Podrobnosti ponudbe
- ID ponudbe:
- A21142277
- Št. reference:
- 554
- Nazadnje posodobljeno:
- dne 02.02.2026
Opis
These scraped surface heat exchangers can be used for the heating process of various products, such as tomato paste, puddings, margarines, oils, mayonnaise, etc. We have completely overhauled these units by renewing internal seals, rings, sandblasting, painting, installing a new stainless steel frame, new controls, and engine testing and maintenance.
TECHNICAL DETAILS OF THE VOTATOR
* Brand: A. Johnson & Co London
* Year of overhaul: 2025
* Quantity: 5 units
* Diameter: 6 inches
* Metals: 316 grade stainless steel
* Application: horizontal votators
SPECIFICATIONS:
* Chamber dimensions: 6" diameter stainless steel chamber
* Length: 6'
* 1 1/2" between end plates
* Rotating center: 4 3/4" diameter stainless steel
* Equipped with two PTFE scraper blades
* Drive: 11 kW motor drives
Redpfx Aboygh Egshsn
* Speed: 1470 rpm (via V-belt reduction)
* Reducer: results in a shaft speed of approx. 367 rpm
AVAILABILITY:
* Location: In stock
* Available: Immediately
GENERAL FORMULA FOR CAPACITY ESTIMATION:
For a VOTATOR, the capacity can be approximated using the following formula:
[ \text{Capacity} = \text{Chamber Volume} \times \text{Turnover Rate} ]
STEP 1: CALCULATE THE CHAMBER VOLUME
The volume of a cylindrical chamber can be calculated as follows:
[ V = \pi \times r^2 \times h ]
Where:
* (r) = radius (half the diameter in inches)
* (h) = height (length of the chamber in inches)
Given:
* Diameter = 6 inches, thus radius ( r = \frac{6}{2} = 3 ) inches
* Length ( h = 6 \text{ ft} = 72 \text{ inches} )
Volume calculation:
[ V = \pi \times (3)^2 \times 72 \approx \pi \times 9 \times 72 \approx 2036.75 cubic inches ]
To convert cubic inches into liters (since 1 cubic inch = 0.0163871 liters):
[ V \approx 2036.75 \times 0.0163871 \approx 33.39 liters ]
STEP 2: ESTIMATE THE TURNOVER RATE
The turnover rate depends on the speed of the VOTATOR and how often the chamber content can be processed. At a shaft speed of approx. 367 rpm, you can estimate about 1 turnover per minute for a basic estimation.
FINAL CAPACITY ESTIMATION
Assuming 1 turnover per minute:
[ \text{Capacity} \approx 33.39 \text{ liters/min} ]
CONCLUSION
The estimated capacity of each VOTATOR is approximately 33.39 liters per minute.
CAPACITY CALCULATION:
* Estimated capacity: 33.39 liters/minute
CONVERT TO LITERS PER HOUR:
[ \text{Capacity per hour} = 33.39 , \text{liters/min} \times 60 , \text{min/hour} ]
[ \text{Capacity per hour} \approx 2003.4 , \text{liters/hour} ]
CONCLUSION
The estimated capacity of each VOTATOR is approximately 2003.4 liters per hour.
Oglas je bil preveden samodejno, zaradi česar je morda prišlo do napak pri prevodu.
TECHNICAL DETAILS OF THE VOTATOR
* Brand: A. Johnson & Co London
* Year of overhaul: 2025
* Quantity: 5 units
* Diameter: 6 inches
* Metals: 316 grade stainless steel
* Application: horizontal votators
SPECIFICATIONS:
* Chamber dimensions: 6" diameter stainless steel chamber
* Length: 6'
* 1 1/2" between end plates
* Rotating center: 4 3/4" diameter stainless steel
* Equipped with two PTFE scraper blades
* Drive: 11 kW motor drives
Redpfx Aboygh Egshsn
* Speed: 1470 rpm (via V-belt reduction)
* Reducer: results in a shaft speed of approx. 367 rpm
AVAILABILITY:
* Location: In stock
* Available: Immediately
GENERAL FORMULA FOR CAPACITY ESTIMATION:
For a VOTATOR, the capacity can be approximated using the following formula:
[ \text{Capacity} = \text{Chamber Volume} \times \text{Turnover Rate} ]
STEP 1: CALCULATE THE CHAMBER VOLUME
The volume of a cylindrical chamber can be calculated as follows:
[ V = \pi \times r^2 \times h ]
Where:
* (r) = radius (half the diameter in inches)
* (h) = height (length of the chamber in inches)
Given:
* Diameter = 6 inches, thus radius ( r = \frac{6}{2} = 3 ) inches
* Length ( h = 6 \text{ ft} = 72 \text{ inches} )
Volume calculation:
[ V = \pi \times (3)^2 \times 72 \approx \pi \times 9 \times 72 \approx 2036.75 cubic inches ]
To convert cubic inches into liters (since 1 cubic inch = 0.0163871 liters):
[ V \approx 2036.75 \times 0.0163871 \approx 33.39 liters ]
STEP 2: ESTIMATE THE TURNOVER RATE
The turnover rate depends on the speed of the VOTATOR and how often the chamber content can be processed. At a shaft speed of approx. 367 rpm, you can estimate about 1 turnover per minute for a basic estimation.
FINAL CAPACITY ESTIMATION
Assuming 1 turnover per minute:
[ \text{Capacity} \approx 33.39 \text{ liters/min} ]
CONCLUSION
The estimated capacity of each VOTATOR is approximately 33.39 liters per minute.
CAPACITY CALCULATION:
* Estimated capacity: 33.39 liters/minute
CONVERT TO LITERS PER HOUR:
[ \text{Capacity per hour} = 33.39 , \text{liters/min} \times 60 , \text{min/hour} ]
[ \text{Capacity per hour} \approx 2003.4 , \text{liters/hour} ]
CONCLUSION
The estimated capacity of each VOTATOR is approximately 2003.4 liters per hour.
Oglas je bil preveden samodejno, zaradi česar je morda prišlo do napak pri prevodu.
Ponudnik
Opomba: Brezplačno se registrirajte ali prijavite, za dostop do vseh informacij.
Registriran od: 2017
Pošlji zahtevo
Telefon & Faks
+44 1332 ... oglasi
Vaš oglas je bil uspešno izbrisan
Prišlo je do napake