Opis
Zwick / Roell
Type: Mflow
Application Area
With increasing testing demands, the need for a higher degree of automation also rises (compared to the Cflow). The Mflow is a modular, expandable device that allows you to determine the melt mass-flow rate (MFR) and the melt volume-flow rate (MVR).
The Mflow melt flow tester, in its basic configuration, is designed for MFR testing according to Method A and can be expanded for MVR testing according to Method B. Testing in compliance with the following standards is possible:
• Methods A and B according to ISO 1133
• Methods A, B, and C according to ASTM D 1238
• ASTM D 3364
• JIS K 7210
Optionally, the Mflow can be equipped with, for example, pneumatic weight lifting—with or without cleaning function—or weight selection.
The Mflow can be operated either as a standalone device via a modern touch display or controlled from a PC using ZwickRoell testing software.
Technical Data
Test Load: 0.325 - 21.6 kg
Compressed air, oiled, dry: 6 - 10 bar
Dimensions
Height: 510 mm
Dedpjtq Em Tjfx Ag Njku
Width: 360 mm
Depth: 419 mm
Weight approx.: 43 kg
Test temperature: +50°C - +450°C
Display: Capacitive touch display
Temperature display resolution: < 0.1 K
Number of storable parameter sets: >100
Temperature accuracy in the range 0 - 75 mm above the nozzle at 50°C - 450°C: < 0.3 K
Time Measurement
Error limit (Method A): ± 0.02 (with automatic cut-off device)
Error limit (Method B): ± 0.01
Displacement Measurement
Error limit (Method B): ±0.02 mm (ISO 1133) / ±0.4% of 6.25 mm (ASTM D 1238)
Resolution: < 0.005
Multiple device operation per PC:
Minimum available RAM: 1.54 GB
Processor speed: 3 GHz
Number of connectable Mflow flow testers per PC: 6
Power supply: 220 - 240 V, 1L/PE/N
Current consumption: 2.6 A
Mains frequency: 50/60 Hz
Software version: V4.2
Year of manufacture: 2021
Condition: used
Scope of delivery: (see photo)
(Technical data subject to change and errors reserved!)
For further questions, we are happy to assist you by phone.
Oglas je bil preveden samodejno, zaradi česar je morda prišlo do napak pri prevodu.
Type: Mflow
Application Area
With increasing testing demands, the need for a higher degree of automation also rises (compared to the Cflow). The Mflow is a modular, expandable device that allows you to determine the melt mass-flow rate (MFR) and the melt volume-flow rate (MVR).
The Mflow melt flow tester, in its basic configuration, is designed for MFR testing according to Method A and can be expanded for MVR testing according to Method B. Testing in compliance with the following standards is possible:
• Methods A and B according to ISO 1133
• Methods A, B, and C according to ASTM D 1238
• ASTM D 3364
• JIS K 7210
Optionally, the Mflow can be equipped with, for example, pneumatic weight lifting—with or without cleaning function—or weight selection.
The Mflow can be operated either as a standalone device via a modern touch display or controlled from a PC using ZwickRoell testing software.
Technical Data
Test Load: 0.325 - 21.6 kg
Compressed air, oiled, dry: 6 - 10 bar
Dimensions
Height: 510 mm
Dedpjtq Em Tjfx Ag Njku
Width: 360 mm
Depth: 419 mm
Weight approx.: 43 kg
Test temperature: +50°C - +450°C
Display: Capacitive touch display
Temperature display resolution: < 0.1 K
Number of storable parameter sets: >100
Temperature accuracy in the range 0 - 75 mm above the nozzle at 50°C - 450°C: < 0.3 K
Time Measurement
Error limit (Method A): ± 0.02 (with automatic cut-off device)
Error limit (Method B): ± 0.01
Displacement Measurement
Error limit (Method B): ±0.02 mm (ISO 1133) / ±0.4% of 6.25 mm (ASTM D 1238)
Resolution: < 0.005
Multiple device operation per PC:
Minimum available RAM: 1.54 GB
Processor speed: 3 GHz
Number of connectable Mflow flow testers per PC: 6
Power supply: 220 - 240 V, 1L/PE/N
Current consumption: 2.6 A
Mains frequency: 50/60 Hz
Software version: V4.2
Year of manufacture: 2021
Condition: used
Scope of delivery: (see photo)
(Technical data subject to change and errors reserved!)
For further questions, we are happy to assist you by phone.