20m³ OFFLINE - FLUORINATION
Fluorination of plastic surfaces with reactive gases for permeation reduction
The technology used is suitable for treating surfaces of plastic fuel tanks (PFT) with the help of fluorine gas mixture (10% F2/N2) and changing the surface properties in such a way that a desired reduction of permeation of fuels from the PFT into the environment and thus the emission of fuel vapors is significantly reduced.
Technical data:
Vacuum chamber (capacity): 20 m3
Process time, individual: (approx. 2.5 hrs.)
Chamber temperature, jacket: 90 - 100 °C
Products introduced: Fuel tank and accessories
Material: stainless steel 1.4301 and similar
Min. vacuum pressure: 1 mbar (a)
Process pressure : 350 - 700 mbar (a)
Nitrogen inlet pressure : 15 bar(g)
F2/N2 inlet pressure : 150 bar, alternatively 100 bar
Gas mixture 1 10% F2 in N2
Gas mixture 2 20% F2 in N2 as gas mixture
MAK values H, HH 0.1 ppm F2, 0.2 ppm F2
Supply voltage 400 V
Frequency 50 Hz
Nsdpfxoid Ngds Aczjdd
Connected load, max. 200 kW
Back-up fuse 150 A
The fluorination plant consists of the following components:
- A treatment chamber (20m3), into which the plastic material to be fluorinated can be placed in material baskets/boxes suitable for this purpose,
- A bundling station for fluorine-nitrogen mixtures Bottle bundles of 12x50 liters for 10% F2/N2 at 150 bar and 20% F2/N2 mixtures at 100 bar,
- Amature panel for nitrogen supply of the process flow,
- Vacuum pumping station in a container, for conditioning and disposal of the treatment chamber
- Heating system for temperature control of the treatment chamber
- Control cabinet with a programmable logic controller S7/ WIN CC7
- Operator control station for process monitoring, process parameter setting and the visualized plant picture, as well as the trend control, the error message system, the protocol output,
- Al2O3 absorber (silo)
Dimensions:
Lower unit: vacuum chamber heated, with control cabinet.
length: 7500mm
width: 2850mm
height: 2380mm
weight approx. 12.000 Kg
Upper unit: pump chamber
Length: 4100mm
width: 2850mm
height: 3000mm
Weight approx. 5.000 Kg
Fluorination of plastic surfaces with reactive gases for permeation reduction
The technology used is suitable for treating surfaces of plastic fuel tanks (PFT) with the help of fluorine gas mixture (10% F2/N2) and changing the surface properties in such a way that a desired reduction of permeation of fuels from the PFT into the environment and thus the emission of fuel vapors is significantly reduced.
Technical data:
Vacuum chamber (capacity): 20 m3
Process time, individual: (approx. 2.5 hrs.)
Chamber temperature, jacket: 90 - 100 °C
Products introduced: Fuel tank and accessories
Material: stainless steel 1.4301 and similar
Min. vacuum pressure: 1 mbar (a)
Process pressure : 350 - 700 mbar (a)
Nitrogen inlet pressure : 15 bar(g)
F2/N2 inlet pressure : 150 bar, alternatively 100 bar
Gas mixture 1 10% F2 in N2
Gas mixture 2 20% F2 in N2 as gas mixture
MAK values H, HH 0.1 ppm F2, 0.2 ppm F2
Supply voltage 400 V
Frequency 50 Hz
Nsdpfxoid Ngds Aczjdd
Connected load, max. 200 kW
Back-up fuse 150 A
The fluorination plant consists of the following components:
- A treatment chamber (20m3), into which the plastic material to be fluorinated can be placed in material baskets/boxes suitable for this purpose,
- A bundling station for fluorine-nitrogen mixtures Bottle bundles of 12x50 liters for 10% F2/N2 at 150 bar and 20% F2/N2 mixtures at 100 bar,
- Amature panel for nitrogen supply of the process flow,
- Vacuum pumping station in a container, for conditioning and disposal of the treatment chamber
- Heating system for temperature control of the treatment chamber
- Control cabinet with a programmable logic controller S7/ WIN CC7
- Operator control station for process monitoring, process parameter setting and the visualized plant picture, as well as the trend control, the error message system, the protocol output,
- Al2O3 absorber (silo)
Dimensions:
Lower unit: vacuum chamber heated, with control cabinet.
length: 7500mm
width: 2850mm
height: 2380mm
weight approx. 12.000 Kg
Upper unit: pump chamber
Length: 4100mm
width: 2850mm
height: 3000mm
Weight approx. 5.000 Kg
Ponudnik
Opomba: Brezplačno se registrirajte ali prijavite, za dostop do vseh informacij.
Registriran od: 2016
Pošlji zahtevo
Telefon & Faks
+49 7251 ... oglasi
Ti oglasi bi vas prav tako lahko zanimali.
mali oglas
Budel
893 km
Pfeiffer C590 PVD Evap.Sputtering sistem
PfeifferC590
PfeifferC590
mali oglas
Lublin
797 km
Hladilna/topilna črpalka
New Aircooled chiller CLIMAVENETANECS NR SL S 0704 159.7 kW/178 kW
New Aircooled chiller CLIMAVENETANECS NR SL S 0704 159.7 kW/178 kW
Vaš oglas je bil uspešno izbrisan
Prišlo je do napake