Klimatska komora z vlago 34 litrovWeiss
WKL 34/60 -60°C bis 150°C
Klimatska komora z vlago 34 litrov
Weiss
WKL 34/60 -60°C bis 150°C
Stanje
Rabljeno
Lokacija
Borken 

Prikaži slike
Prikaži karto
Podatki o stroju
Cena in lokacija
- Lokacija:
- Einsteinstraße 8a, 46325 Borken, DE
Klic
Podrobnosti ponudbe
- ID ponudbe:
- A16211179
- Št. reference:
- 24134
- Nazadnje posodobljeno:
- dne 15.11.2024
Opis
Weiss
Model: WKL 34/60
Weiss Climate Chamber, Air-Cooled
Refrigerant converted to R-452A
-60°C to +150°C
Chamber volume: 34 liters
Gksdpfjtr Dinex Ah Doc
Feedthroughs included in standard configuration:
R1 NW 50 mm
L1 NW 120 mm
Internal dimensions: Height 310 mm, Width 324 mm, Depth 300 mm
External dimensions: Height 1740 mm, Width 630 mm, Depth 970 mm
Performance Data for Temperature Testing:
Temperature range: -60 to +150 °C
Temperature variation in stabilized state (per IEC 60068-3-5):
Temporal temperature fluctuation at center of workspace: ± 0.3 to ± 1 K, ± 1 to ± 2 K
Spatial temperature deviation (temperature gradient): 2 to 4
Temperature change rate (per IEC 60068-3-5):
Heating: 2.5 K/min
Cooling: 3 K/min
Maximum heat compensation: 550 W
Performance Data for Climate Testing:
Temperature range: +10 to +95 °C
Humidity range: 10 to 98 % r.h.
Temperature and humidity deviations (in stabilized state, per IEC 60068-3-5):
Temporal temperature fluctuation at center of workspace: ± 0.3 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
(temperature gradient): 1 to 3
Temporal humidity fluctuation at center of workspace: ± 3 to ± 5 % r.h.
Operating Data:
Test chamber lighting: Halogen bulb 12V, 20W
Nominal voltage: 1/N / PE AC 230 V ± 10 %, 50 Hz
Nominal power: 2.5 kW
Nominal current: 11 A
Required customer-side fuse: 16A slow-blow
Heat dissipation for air-cooled chambers:
Max. heat emission to environment: 1700 W
Refrigerants: R-452A / R23
Weight: 140 kg
For your safety as a buyer, please note the following:
The following steps are carried out on our offered chambers in advance:
1. Functional test and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Subject to technical modifications and errors, all details are non-binding!)
If you have any further questions, we are happy to answer your calls.
Oglas je bil preveden samodejno, zaradi česar je morda prišlo do napak pri prevodu.
Model: WKL 34/60
Weiss Climate Chamber, Air-Cooled
Refrigerant converted to R-452A
-60°C to +150°C
Chamber volume: 34 liters
Gksdpfjtr Dinex Ah Doc
Feedthroughs included in standard configuration:
R1 NW 50 mm
L1 NW 120 mm
Internal dimensions: Height 310 mm, Width 324 mm, Depth 300 mm
External dimensions: Height 1740 mm, Width 630 mm, Depth 970 mm
Performance Data for Temperature Testing:
Temperature range: -60 to +150 °C
Temperature variation in stabilized state (per IEC 60068-3-5):
Temporal temperature fluctuation at center of workspace: ± 0.3 to ± 1 K, ± 1 to ± 2 K
Spatial temperature deviation (temperature gradient): 2 to 4
Temperature change rate (per IEC 60068-3-5):
Heating: 2.5 K/min
Cooling: 3 K/min
Maximum heat compensation: 550 W
Performance Data for Climate Testing:
Temperature range: +10 to +95 °C
Humidity range: 10 to 98 % r.h.
Temperature and humidity deviations (in stabilized state, per IEC 60068-3-5):
Temporal temperature fluctuation at center of workspace: ± 0.3 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
(temperature gradient): 1 to 3
Temporal humidity fluctuation at center of workspace: ± 3 to ± 5 % r.h.
Operating Data:
Test chamber lighting: Halogen bulb 12V, 20W
Nominal voltage: 1/N / PE AC 230 V ± 10 %, 50 Hz
Nominal power: 2.5 kW
Nominal current: 11 A
Required customer-side fuse: 16A slow-blow
Heat dissipation for air-cooled chambers:
Max. heat emission to environment: 1700 W
Refrigerants: R-452A / R23
Weight: 140 kg
For your safety as a buyer, please note the following:
The following steps are carried out on our offered chambers in advance:
1. Functional test and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Subject to technical modifications and errors, all details are non-binding!)
If you have any further questions, we are happy to answer your calls.