Klimatska preskusna komora z vlažnostjo 335 litrovWeiss
WK3-340/40 -42°C bis +180°C
Klimatska preskusna komora z vlažnostjo 335 litrov
Weiss
WK3-340/40 -42°C bis +180°C
Stanje
Rabljeno
Lokacija
Borken 

Prikaži slike
Prikaži karto
Podatki o stroju
- Proizvajalec:
- Weiss
- Stanje:
- zelo dobro (rabljeno)
Cena in lokacija
- Lokacija:
- Einsteinstraße 8a, 46325 Borken, DE
Klic
Prodaja strojev

Ste našli novo napravo? Zdaj staro pretvorite v denar.
Dosežite najboljšo ceno prek Machineseeker.
Več o prodaji strojev
Več o prodaji strojev
Podrobnosti ponudbe
- ID ponudbe:
- A14677090
- Št. reference:
- 23948
- Nazadnje posodobljeno:
- dne 15.11.2024
Opis
Here we are offering a Weiss climate test chamber.
Weiss Climate Test Chamber, water-cooled
(Refrigerant converted to R-452A)
Temperature Testing
Fpodeq U Sdcepfx Ah Don
Volume: 335 liters
Test chamber dimensions:
Internal dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Minimum temperature: –42°C
Maximum temperature: +180°C
Temperature change rate, cooling: 4 K/min
Temperature change rate, heating: 3.2 K/min
Temporal temperature deviation: ± 0.1 to ± 0.5 K
Spatial temperature uniformity: ± 0.5 to ± 1.5 K
Climatic testing:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% r.h.
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature uniformity: ± 0.5 to ± 1 K
Temporal humidity deviation: ± 1 to ± 3 % r.h.
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power: 4.1 kW Rated current: 14 A
Refrigerant: R-452A
Model: WK3-340/40
Weight: approx. 515 kg
For your safety as a buyer, please note the following information!
The following measures are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Specifications and technical data may be subject to change and errors!)
For further questions, feel free to contact us by phone.
Oglas je bil preveden samodejno, zaradi česar je morda prišlo do napak pri prevodu.
Weiss Climate Test Chamber, water-cooled
(Refrigerant converted to R-452A)
Temperature Testing
Fpodeq U Sdcepfx Ah Don
Volume: 335 liters
Test chamber dimensions:
Internal dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Minimum temperature: –42°C
Maximum temperature: +180°C
Temperature change rate, cooling: 4 K/min
Temperature change rate, heating: 3.2 K/min
Temporal temperature deviation: ± 0.1 to ± 0.5 K
Spatial temperature uniformity: ± 0.5 to ± 1.5 K
Climatic testing:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% r.h.
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature uniformity: ± 0.5 to ± 1 K
Temporal humidity deviation: ± 1 to ± 3 % r.h.
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power: 4.1 kW Rated current: 14 A
Refrigerant: R-452A
Model: WK3-340/40
Weight: approx. 515 kg
For your safety as a buyer, please note the following information!
The following measures are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Specifications and technical data may be subject to change and errors!)
For further questions, feel free to contact us by phone.
Oglas je bil preveden samodejno, zaradi česar je morda prišlo do napak pri prevodu.
Ponudnik
Opomba: Brezplačno se registrirajte ali prijavite, za dostop do vseh informacij.
Pošlji zahtevo
Telefon & Faks
+49 2861 ... oglasi
Vaš oglas je bil uspešno izbrisan
Prišlo je do napake