Weiss climate test chamber with seat pulsator
Manufacturer: Weiss
Model: SD 1400/+20 DU
Test Chamber:
Material: Stainless Steel
Dimensions
Height: approx. 800 mm
Width: approx. 2000 mm
Depth: approx. 900 mm
Gjdpfx Ahjxbgrgo Djbu
Volume: 1440 liters
External Housing:
Material: double-coated Zincor sheet
Dimensions
Height: approx. 2000 mm
Width: approx. 2200 mm
Depth: approx. 2000 mm
HxWxD 2000 x 2200 x 2000 mm
Paint finish: light grey (RAL 9002)
Door, double-leaf: hinged left and right
Equipment:
Port openings in floor and ceiling: 2 each, nominal width 100 mm, for the integration of pulsation tables
Port openings in side walls: 1 each, left and right, 100 mm
Refrigeration unit: air-cooled
Control system: Digital Measurement and Control System DMR
Basic operating unit: integrated into main switch panel
Interface: RS 232 C, for connection to a PC
Software: Operating software for MS Windows
Performance Data:
Temperature range without climate control: +20...+100 °C
Temperature constancy without climate control: +0.2 … +0.5 K (over time), depending on range, at steady state
Temperature range with climate control: 20...+95 °C
Temperature constancy with climate control: +0.2 ... +0.5 K (over time), depending on range, at steady state
Dew point range: 20...+94 °C
Humidity range: 10...98% r.h.
Humidity constancy: +3...+5% r.h., depending on range, at steady state
Temperature change rate measured at outlet, without sample and load:
- Cooling: 0.5 K/min average, between +100 and +20 °C
- Heating: 0.5 K/min average, between +20 and +100 °C
Performance data refer to an ambient temperature of max. +25 °C and the specified nominal voltage. For proper operation, the ambient temperature must be between +10 and +35 °C.
Seat test device with steel frame for mounting and securing on the climate test chamber, including:
• 2 pneumatic weight lifting devices (150 mm stroke) for test specimen change, 12 weights of 5 kg each
• 1 base frame in standard welded steel construction for fastening to the underside of the climate test chamber. This frame is fitted on all sides with removable panels and features 2 hinged doors for adjusting eccentricity. These doors are equipped with safety switches.
• 2 eccentric cams with bearings and tachometer; 2 connecting rods; 2 ball guides
• 2 perforated assembly tables, 20 mm grid, 650 x 650 mm, for connecting test specimens, made of aluminum, min. thickness 10 mm
• 2 perforated mounting plates, 20 mm grid, 200 x 200 mm, for connecting buttock simulation
• 2 loading rods Ø 60, made of stainless steel (connection to the test specimen is not included in our price, but can be offered separately after precise definition)
• 2 three-phase motors; 2 belt drives with tensioners
• 1 pneumatic control system with 2 manual valves, a filter-regulator unit, and a shut-off valve; 1 electrical control cabinet with 2 SEW frequency converters, manual switch, emergency stop button, 2 start buttons, 2 stop buttons, 2 speed displays, 2 potentiometers for speed adjustment, 2 preset load cycle counters with reset and cut-off
Technical Data:
Frequency: 100-1000 cycles/min
Load: 2 x 45 kg
Stroke: 0 - 40 mm
Top load: 450 N each
More items – new and used – can be found in our shop!
International shipping costs on request!
Oglas je bil preveden samodejno, zaradi česar je morda prišlo do napak pri prevodu.
Manufacturer: Weiss
Model: SD 1400/+20 DU
Test Chamber:
Material: Stainless Steel
Dimensions
Height: approx. 800 mm
Width: approx. 2000 mm
Depth: approx. 900 mm
Gjdpfx Ahjxbgrgo Djbu
Volume: 1440 liters
External Housing:
Material: double-coated Zincor sheet
Dimensions
Height: approx. 2000 mm
Width: approx. 2200 mm
Depth: approx. 2000 mm
HxWxD 2000 x 2200 x 2000 mm
Paint finish: light grey (RAL 9002)
Door, double-leaf: hinged left and right
Equipment:
Port openings in floor and ceiling: 2 each, nominal width 100 mm, for the integration of pulsation tables
Port openings in side walls: 1 each, left and right, 100 mm
Refrigeration unit: air-cooled
Control system: Digital Measurement and Control System DMR
Basic operating unit: integrated into main switch panel
Interface: RS 232 C, for connection to a PC
Software: Operating software for MS Windows
Performance Data:
Temperature range without climate control: +20...+100 °C
Temperature constancy without climate control: +0.2 … +0.5 K (over time), depending on range, at steady state
Temperature range with climate control: 20...+95 °C
Temperature constancy with climate control: +0.2 ... +0.5 K (over time), depending on range, at steady state
Dew point range: 20...+94 °C
Humidity range: 10...98% r.h.
Humidity constancy: +3...+5% r.h., depending on range, at steady state
Temperature change rate measured at outlet, without sample and load:
- Cooling: 0.5 K/min average, between +100 and +20 °C
- Heating: 0.5 K/min average, between +20 and +100 °C
Performance data refer to an ambient temperature of max. +25 °C and the specified nominal voltage. For proper operation, the ambient temperature must be between +10 and +35 °C.
Seat test device with steel frame for mounting and securing on the climate test chamber, including:
• 2 pneumatic weight lifting devices (150 mm stroke) for test specimen change, 12 weights of 5 kg each
• 1 base frame in standard welded steel construction for fastening to the underside of the climate test chamber. This frame is fitted on all sides with removable panels and features 2 hinged doors for adjusting eccentricity. These doors are equipped with safety switches.
• 2 eccentric cams with bearings and tachometer; 2 connecting rods; 2 ball guides
• 2 perforated assembly tables, 20 mm grid, 650 x 650 mm, for connecting test specimens, made of aluminum, min. thickness 10 mm
• 2 perforated mounting plates, 20 mm grid, 200 x 200 mm, for connecting buttock simulation
• 2 loading rods Ø 60, made of stainless steel (connection to the test specimen is not included in our price, but can be offered separately after precise definition)
• 2 three-phase motors; 2 belt drives with tensioners
• 1 pneumatic control system with 2 manual valves, a filter-regulator unit, and a shut-off valve; 1 electrical control cabinet with 2 SEW frequency converters, manual switch, emergency stop button, 2 start buttons, 2 stop buttons, 2 speed displays, 2 potentiometers for speed adjustment, 2 preset load cycle counters with reset and cut-off
Technical Data:
Frequency: 100-1000 cycles/min
Load: 2 x 45 kg
Stroke: 0 - 40 mm
Top load: 450 N each
More items – new and used – can be found in our shop!
International shipping costs on request!
Oglas je bil preveden samodejno, zaradi česar je morda prišlo do napak pri prevodu.
Ponudnik
Opomba: Brezplačno se registrirajte ali prijavite, za dostop do vseh informacij.
Pošlji zahtevo
Telefon & Faks
+49 2862 ... oglasi
Vaš oglas je bil uspešno izbrisan
Prišlo je do napake