Klimatska preskusna komora z vlagoWeiss -72°C bis +180°C
WK3-340/70
Klimatska preskusna komora z vlago
Weiss -72°C bis +180°C
WK3-340/70
Stanje
Rabljeno
Lokacija
Borken 

Podatki o stroju
- Oznaka stroja:
- Klimatska preskusna komora z vlago
- Proizvajalec:
- Weiss -72°C bis +180°C
- Model:
- WK3-340/70
- Stanje:
- zelo dobro (rabljeno)
Cena in lokacija
- Lokacija:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Pokliči
Podrobnosti ponudbe
- ID oglasa:
- A22257232
- Referenčna številka:
- 24566
- Posodobitev:
- nazadnje dne 03.07.2026
Opis
Weiss
Model: WK3-340/70
Weiss Climate Test Chamber, Air-Cooled
Control Unit: Touchpanel
All control and operating commands can be activated on the "Touchpanel" control unit by simply touching the function icons.
Adjustable Feet
To compensate for floor unevenness and to ensure sufficient ventilation of the machine section, the test chamber is equipped with adjustable feet.
Feedthroughs
The test chamber is fitted with feedthroughs on the right and left sides. These allow measuring cables and test fixtures to be routed into the test chamber.
Feedthroughs installed as standard:
R1: Nominal Width 125 mm
L1: Nominal Width 85 mm
Volume: 335 liters
Test Chamber Internal Dimensions:
Height 750 mm, Width 580 mm, Depth 765 mm
External Dimensions:
Height 1775 mm, Width 870 mm, Depth 1600 mm
Data for Temperature Tests:
Minimum Temperature: –72°C
Maximum Temperature: +180°C
Temperature Deviation, over time: ± 0.1 to ± 0.5 K
Temperature Uniformity, spatial: ± 0.5 to ± 1.5 K
Temperature Change Rate, Cooling: 3 K/min
Temperature Change Rate, Heating: 3 K/min
Data for Climate Tests:
Temperature Range: +10°C to +95°C
Dew Point Range: -3°C to +94°C
Humidity Range: 10 to 98% r.h.
Temperature Deviation, over time: ± 0.1 to ± 0.3 K
Dodpfsziiwujx Abgoci
Temperature Uniformity, spatial: ± 0.5 to ± 1 K
Humidity Deviation, over time: ± 1 to ± 3% r.h.
Operating Data:
Test Chamber Lighting: Halogen bulbs 2 x 24V, 50W
Rated Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated Current: 16 A
Rated Power: 4.9 kW
Circuit Breaker (on-site): 16 A slow-blow
Refrigerant: R-452A/R23
Weight: approx. 585 kg
For your security as the buyer, please note the following information!
The following items are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certification
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data and information reserved!)
Feel free to contact us by phone for further questions.
Oglas je bil avtomatsko preveden. Možne so napake pri prevodu.
Model: WK3-340/70
Weiss Climate Test Chamber, Air-Cooled
Control Unit: Touchpanel
All control and operating commands can be activated on the "Touchpanel" control unit by simply touching the function icons.
Adjustable Feet
To compensate for floor unevenness and to ensure sufficient ventilation of the machine section, the test chamber is equipped with adjustable feet.
Feedthroughs
The test chamber is fitted with feedthroughs on the right and left sides. These allow measuring cables and test fixtures to be routed into the test chamber.
Feedthroughs installed as standard:
R1: Nominal Width 125 mm
L1: Nominal Width 85 mm
Volume: 335 liters
Test Chamber Internal Dimensions:
Height 750 mm, Width 580 mm, Depth 765 mm
External Dimensions:
Height 1775 mm, Width 870 mm, Depth 1600 mm
Data for Temperature Tests:
Minimum Temperature: –72°C
Maximum Temperature: +180°C
Temperature Deviation, over time: ± 0.1 to ± 0.5 K
Temperature Uniformity, spatial: ± 0.5 to ± 1.5 K
Temperature Change Rate, Cooling: 3 K/min
Temperature Change Rate, Heating: 3 K/min
Data for Climate Tests:
Temperature Range: +10°C to +95°C
Dew Point Range: -3°C to +94°C
Humidity Range: 10 to 98% r.h.
Temperature Deviation, over time: ± 0.1 to ± 0.3 K
Dodpfsziiwujx Abgoci
Temperature Uniformity, spatial: ± 0.5 to ± 1 K
Humidity Deviation, over time: ± 1 to ± 3% r.h.
Operating Data:
Test Chamber Lighting: Halogen bulbs 2 x 24V, 50W
Rated Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated Current: 16 A
Rated Power: 4.9 kW
Circuit Breaker (on-site): 16 A slow-blow
Refrigerant: R-452A/R23
Weight: approx. 585 kg
For your security as the buyer, please note the following information!
The following items are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certification
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data and information reserved!)
Feel free to contact us by phone for further questions.