- Opis stroja:
- Komora za preskus temperaturnega šoka -70–220°C
- Proizvajalec:
- Vötsch
- Model:
- VT 7012 S2
- Leto izdelave:
- 2000
- Stanje:
- zelo dobro (rabljeno)
- Obratovalne ure:
- 104.382 h
Cena in lokacija
Začetna cena brez DDV
11.025 €
- Lokacija:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Klic
Podrobnosti ponudbe
- ID ponudbe:
- A20729167
- Št. reference:
- 31747
- Nazadnje posodobljeno:
- dne 13.02.2026
Opis
Vötsch Shock Test Chamber VT 7012 S2
System for Extreme Temperature Changes
The temperature shock test evaluates the resistance of components, devices, and other products to rapid changes in ambient temperature. Test specimens are subjected to rapid temperature changes in air, alternating between upper and lower temperature levels under varying load conditions. Through these cyclic stresses and temperature-change-induced accelerated aging, potential weaknesses in the specimen can be identified.
- Vertical arrangement of test chambers
- Ball screw drive for secure carriage guidance
- Carriage load capacity: 50 kg (VT3 7012 S2)
- All-around mesh baskets secure the test specimens
- High air circulation rate for short temperature change times and even temperature distribution in the test chamber
- Warm chamber can be used as a temperature storage unit; cold chamber can be used as a temperature cycling unit
- Minimal energy consumption
- No compressed air required
Manufacturer: Vötsch
Rjdpfx Agex Exmts Tsp
Model: VT 7012 S2
Type: Temperature Shock Test Chamber
Test Chamber Volume: 120 l
Rated Voltage: 400 V
Rated Power: 10 kW
Rated Current: 25 A
Refrigerant: R452A
Cooling Unit: Water-cooled
Shock Cooling (nitrogen cooling) via customer-supplied liquid nitrogen feed
External Dimensions:
Width: 930 mm
Depth: 2115 mm
Height: 1970 mm
Test Chamber Dimensions:
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Protection Class:
Device: IP 42
Control unit: IP20
Switch cabinet: IP 54
Key Parameters for Temperature Tests in Single-Chamber Operation:
Temperature Range:
Warm chamber: +50°C to +220°C
Cold chamber: -70°C to +70°C
Temperature deviation over time: ±2 K (in steady state)
Temperature deviation spatially: ±2 K (in steady state within carriage)
Warm chamber heating rate: 11 K/min
Cold chamber cooling rate: K/min
Cold chamber heating rate: 2 K/min
Warm chamber cooling rate: K/min
Observation window: 355 x 355 mm
Cable port: 67 mm
Year of manufacture: 2000
Operating hours: 104382
Weight: 1000 kg
Financing through our partner bank is available.
komplett-konzept.leasingo.de
More articles—new and used—can be found in our shop! International shipping rates upon request!
Oglas je bil preveden samodejno, zaradi česar je morda prišlo do napak pri prevodu.
System for Extreme Temperature Changes
The temperature shock test evaluates the resistance of components, devices, and other products to rapid changes in ambient temperature. Test specimens are subjected to rapid temperature changes in air, alternating between upper and lower temperature levels under varying load conditions. Through these cyclic stresses and temperature-change-induced accelerated aging, potential weaknesses in the specimen can be identified.
- Vertical arrangement of test chambers
- Ball screw drive for secure carriage guidance
- Carriage load capacity: 50 kg (VT3 7012 S2)
- All-around mesh baskets secure the test specimens
- High air circulation rate for short temperature change times and even temperature distribution in the test chamber
- Warm chamber can be used as a temperature storage unit; cold chamber can be used as a temperature cycling unit
- Minimal energy consumption
- No compressed air required
Manufacturer: Vötsch
Rjdpfx Agex Exmts Tsp
Model: VT 7012 S2
Type: Temperature Shock Test Chamber
Test Chamber Volume: 120 l
Rated Voltage: 400 V
Rated Power: 10 kW
Rated Current: 25 A
Refrigerant: R452A
Cooling Unit: Water-cooled
Shock Cooling (nitrogen cooling) via customer-supplied liquid nitrogen feed
External Dimensions:
Width: 930 mm
Depth: 2115 mm
Height: 1970 mm
Test Chamber Dimensions:
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Protection Class:
Device: IP 42
Control unit: IP20
Switch cabinet: IP 54
Key Parameters for Temperature Tests in Single-Chamber Operation:
Temperature Range:
Warm chamber: +50°C to +220°C
Cold chamber: -70°C to +70°C
Temperature deviation over time: ±2 K (in steady state)
Temperature deviation spatially: ±2 K (in steady state within carriage)
Warm chamber heating rate: 11 K/min
Cold chamber cooling rate: K/min
Cold chamber heating rate: 2 K/min
Warm chamber cooling rate: K/min
Observation window: 355 x 355 mm
Cable port: 67 mm
Year of manufacture: 2000
Operating hours: 104382
Weight: 1000 kg
Financing through our partner bank is available.
komplett-konzept.leasingo.de
More articles—new and used—can be found in our shop! International shipping rates upon request!
Oglas je bil preveden samodejno, zaradi česar je morda prišlo do napak pri prevodu.
Ponudnik
Opomba: Brezplačno se registrirajte ali prijavite, za dostop do vseh informacij.
Pošlji zahtevo
Telefon & Faks
+49 2862 ... oglasi
Ti oglasi bi vas prav tako lahko zanimali.
Mali oglas
Borken
868 km
Preizkusna komora za udarni test –80 °C do +220 °C
VötschVT 7012 S2
VötschVT 7012 S2
Mali oglas
Borken
868 km
Klimatska komora z vlago, 335 litrov
VötschVC³ 7034 -70°C bis +180°C
VötschVC³ 7034 -70°C bis +180°C
Mali oglas
Borken
868 km
Komora za šok testiranje -80°C do +220°C
VötschVT 7012 S2
VötschVT 7012 S2
Mali oglas
Borken
868 km
Preskusna komora za udarce +50 - 220 °C -80 - +70 °C
VötschVT 7012 S2 (6603)
VötschVT 7012 S2 (6603)
Mali oglas
Borken
868 km
Shaker
LDSV721 / TK 8000/-50/120
LDSV721 / TK 8000/-50/120
Mali oglas
Borken
868 km
Komora za preizkus šoka –75 °C do +220 °C
VötschVT 7012 S2
VötschVT 7012 S2
Mali oglas
Borken
868 km
Preizkusna komora za udarni test –80 °C do +220 °C
VötschVT 7012 S2
VötschVT 7012 S2
Mali oglas
Borken
868 km
Komora za udarne preskuse
VötschVT 7012 S3
VötschVT 7012 S3
Mali oglas
Bodzanów
574 km
Vakuumska črpalka
BuschRA 0160 D
BuschRA 0160 D
Vaš oglas je bil uspešno izbrisan
Prišlo je do napake