Generator za zasilno napajanjeNotstromaggregat 2000 KVA MTU
16v396
Generator za zasilno napajanje
Notstromaggregat 2000 KVA MTU
16v396
Leto izdelave
1996
Stanje
Rabljeno
Lokacija
Königswinter 

Prikaži slike
Prikaži karto
Podatki o stroju
- Opis stroja:
- Generator za zasilno napajanje
- Proizvajalec:
- Notstromaggregat 2000 KVA MTU
- Model:
- 16v396
- Leto izdelave:
- 1996
- Stanje:
- zelo dobro (rabljeno)
- Funkcionalnost:
- popolnoma funkcionalen
- Obratovalne ure:
- 250 h
Cena in lokacija
- Lokacija:
- Hauptstraße 371, 53639 Königswinter, Deutschland

Klic
Podrobnosti ponudbe
- ID ponudbe:
- A18905271
- Nazadnje posodobljeno:
- dne 08.04.2025
Opis
For sale is a 2000 kVA containerized genset.
Selectable 400/230V (50Hz) or 10kV (+/- 5%) (50Hz)
Fully installed inside two sound-insulated 40’-HC containers. Suitable and designed for multi-layer stacking/installation.
Dimensions (LxWxH): 12020 x 2500 x 5800 mm
Weight: approx. 33t + 11t
Engine: MTU 16v396 TB 34D
Generator: A.v. Kaick DIDBN 130/125 h/4
2000 kVA genset: Engine and generator mounted together on a base frame and connected by a flexible coupling.
Cooling system:
Separate table cooler as a dual-circuit cooling unit installed in the upper container, including temperature control, connecting pipes (stainless steel cooling water pipes with shut-off valves for each line), circulating pumps, control valve, etc. for safe operation.
Fuel tank system:
4000-liter tank system installed in the upper container, including all system-required accessories and complete piping.
Intake/Exhaust air system:
Hfjdpfowa Tg Djx Af Tjb
Sound-absorbing baffles within the intake and exhaust air chambers in the container. Each intake and exhaust air opening fitted with appropriate weather protection grilles; motor-actuated louvers inside the container that open automatically during generator operation.
Exhaust system:
Exhaust piping insulated inside the containers—directed vertically via silencers through the upper container to discharge exhaust gases through the container roof.
Switchgear:
Medium/low-voltage switchgear for fully automatic standby power operation!
Selectable 400/230 V or 10 kV (+/-5%)
Fully automatic machine monitoring with control system for mains failure detection, automatic starting, and transfer to emergency power supply. Automatic retransfer to mains supply once grid returns.
Low-voltage parallel operation / re-synchronization is possible.
Control for external mains switch—selectable 10kV or 400/230V.
Low-voltage switchgear equipped with: 3200A generator circuit-breaker (400/230V)
Medium-voltage switchgear equipped with: 115A generator circuit-breaker (10kV)
Technical data of type-tested medium-voltage switchgear
Switchgear type: ZS8
Rated voltage: 12kV
Operating voltage: 10kV
etc.
Oglas je bil preveden samodejno, zaradi česar je morda prišlo do napak pri prevodu.
Selectable 400/230V (50Hz) or 10kV (+/- 5%) (50Hz)
Fully installed inside two sound-insulated 40’-HC containers. Suitable and designed for multi-layer stacking/installation.
Dimensions (LxWxH): 12020 x 2500 x 5800 mm
Weight: approx. 33t + 11t
Engine: MTU 16v396 TB 34D
Generator: A.v. Kaick DIDBN 130/125 h/4
2000 kVA genset: Engine and generator mounted together on a base frame and connected by a flexible coupling.
Cooling system:
Separate table cooler as a dual-circuit cooling unit installed in the upper container, including temperature control, connecting pipes (stainless steel cooling water pipes with shut-off valves for each line), circulating pumps, control valve, etc. for safe operation.
Fuel tank system:
4000-liter tank system installed in the upper container, including all system-required accessories and complete piping.
Intake/Exhaust air system:
Hfjdpfowa Tg Djx Af Tjb
Sound-absorbing baffles within the intake and exhaust air chambers in the container. Each intake and exhaust air opening fitted with appropriate weather protection grilles; motor-actuated louvers inside the container that open automatically during generator operation.
Exhaust system:
Exhaust piping insulated inside the containers—directed vertically via silencers through the upper container to discharge exhaust gases through the container roof.
Switchgear:
Medium/low-voltage switchgear for fully automatic standby power operation!
Selectable 400/230 V or 10 kV (+/-5%)
Fully automatic machine monitoring with control system for mains failure detection, automatic starting, and transfer to emergency power supply. Automatic retransfer to mains supply once grid returns.
Low-voltage parallel operation / re-synchronization is possible.
Control for external mains switch—selectable 10kV or 400/230V.
Low-voltage switchgear equipped with: 3200A generator circuit-breaker (400/230V)
Medium-voltage switchgear equipped with: 115A generator circuit-breaker (10kV)
Technical data of type-tested medium-voltage switchgear
Switchgear type: ZS8
Rated voltage: 12kV
Operating voltage: 10kV
etc.
Oglas je bil preveden samodejno, zaradi česar je morda prišlo do napak pri prevodu.
Ponudnik
Opomba: Brezplačno se registrirajte ali prijavite, za dostop do vseh informacij.
Registriran od: 2021
Pošlji zahtevo
Telefon & Faks
+49 178 6... oglasi
Ti oglasi bi vas prav tako lahko zanimali.
Mali oglas
Voerde (Niederrhein)
858 km
Dekanter
FlottwegC4E-4/454
FlottwegC4E-4/454
Mali oglas
Beveren
967 km
Gosenični bager
Caterpillar374 F L
Caterpillar374 F L
Mali oglas
Langenhagen
798 km
Transformator
Veneta 2500 kVA Gießharz 1997TR 42500, IP00, 20/0,4 kV
Veneta 2500 kVA Gießharz 1997TR 42500, IP00, 20/0,4 kV
Mali oglas
Alsfeld
664 km
Singlefacer Asitrade
AsitradeSinglefacer
AsitradeSinglefacer
Mali oglas
Wiefelstede
932 km
Generator električne energije 730 kVA
MWM/PillerNKTB 4-1158
MWM/PillerNKTB 4-1158
Mali oglas
Herdwangen
483 km
Naprava za analizo vode
SpectroCiros CCD
SpectroCiros CCD
Mali oglas
Berlin
713 km
Notranji cilindrični brusilni stroj
JungC8
JungC8
Mali oglas
Berlin
713 km
Električni motor
ABB
ABB
Mali oglas
Borken
683 km
Generatorski sklop
SDMO
SDMO
Mali oglas
Enschede
896 km
Ploščni valj 4 zvitki
Ostas4R OHS 1570 x 200
Ostas4R OHS 1570 x 200
Vaš oglas je bil uspešno izbrisan
Prišlo je do napake


































































































