Odprti hladilni stolp BAC S15E 1018-10 LEBAC
S1500E
Odprti hladilni stolp BAC S15E 1018-10 LE
BAC
S1500E
VB plus DDV
26.800 €
Stanje
Rabljeno
Lokacija
Borken 

Podatki o stroju
- Oznaka stroja:
- Odprti hladilni stolp BAC S15E 1018-10 LE
- Proizvajalec:
- BAC
- Model:
- S1500E
- Stanje:
- dober (rabljeno)
Cena in lokacija
VB plus DDV
26.800 €
- Lokacija:
- 46325 Borken, Deutschland

Pokliči
Podrobnosti ponudbe
- ID oglasa:
- A21340202
- Referenčna številka:
- 60821
- Posodobitev:
- nazadnje dne 02.06.2026
Opis
BAC S1500E Cooling Tower
The BAC S15E 1018-10-LE is a high-performance open cooling tower from the S1500E series by Baltimore Aircoil Company (BAC).
This specific model is designed for industrial cooling applications and large-scale air conditioning systems (HVAC) where high efficiency and ease of maintenance are essential.
Technology
Lsdpfx Asynkbmehujac
Patented BACross III fill media system, enabling easy inspection of the fill to help prevent biological growth (e.g. Legionella).
Key Features of the S1500E Series
- Maintenance Access: A large inward swinging access door and internal service platforms enable technicians to conveniently perform inspections while standing inside the unit.
- Hygiene Control: The design minimizes stagnant water and the special air inlet components protect against sunlight, effectively reducing algae growth.
- Flexibility: Side air intake allows the cooling tower to be installed in confined spaces or directly against walls.
- Materials: Galvanized steel with Baltibond hybrid coating.
Typical Applications
- Industrial Cooling: Used in factories for process cooling.
- Air Conditioning (HVAC): Employed in large building complexes as part of a central chiller plant.
- Refrigeration: Used as a condenser in commercial refrigeration systems.
Cooling Performance
An open evaporative cooling tower has no fixed, single kW cooling capacity, as the actual capacity is entirely dependent on thermodynamic ambient conditions and system temperatures.
This model is rated for maximum flow rates up to 198 liters per second.
Under typical industrial or HVAC standard conditions, the nominal cooling capacity for this model ranges from approximately 1,200 kW to 2,100 kW.
Why Does Cooling Capacity Vary?
- Wet-bulb temperature (outside air): The cooler and drier the ambient air, the more water can evaporate and the higher the cooling capacity.
- Water temperatures: Performance strongly varies depending on the entering hot water temperature (e.g., 35°C) and exiting cold water temperature (e.g., 29°C).
- Airflow: According to BAC spec, the S15E 1018-10 LE actively moves 60.0 m³/s of air through three integrated 11.0 kW axial fan motors.
If fan speed is reduced by variable frequency drive (for example, during night operation or in winter), cooling capacity decreases proportionally.
- Approach: This is the most important thermodynamic limit. It represents the difference between the desired cold water temperature and the physical wet-bulb temperature. The closer the cold water approaches the wet-bulb temperature (smaller approach), the less kW capacity the tower provides.
Technical Data:
Fan & Air Data
- Airflow: 60.0 m³/s (induced draft)
- Fan Motors: 3 x 11.0 kW (axial fans)
- Technology: Integrated belt drive
- Water flow rate: 198 l/s
Hydraulic Connections
- Water inlet (Fluid Inlet): 1 x DN 250 (nominal diameter 250 mm)
- Water outlet (Fluid Outlet): 1 x DN 300 (nominal diameter 300 mm)
- Make-up Water Connection: 1 x DN 40 (ND 40 mm)
- Overflow / Drain: DN 80 (ND 80 mm) / DN 50 (ND 50 mm)
Oglas je bil avtomatsko preveden. Možne so napake pri prevodu.
The BAC S15E 1018-10-LE is a high-performance open cooling tower from the S1500E series by Baltimore Aircoil Company (BAC).
This specific model is designed for industrial cooling applications and large-scale air conditioning systems (HVAC) where high efficiency and ease of maintenance are essential.
Technology
Lsdpfx Asynkbmehujac
Patented BACross III fill media system, enabling easy inspection of the fill to help prevent biological growth (e.g. Legionella).
Key Features of the S1500E Series
- Maintenance Access: A large inward swinging access door and internal service platforms enable technicians to conveniently perform inspections while standing inside the unit.
- Hygiene Control: The design minimizes stagnant water and the special air inlet components protect against sunlight, effectively reducing algae growth.
- Flexibility: Side air intake allows the cooling tower to be installed in confined spaces or directly against walls.
- Materials: Galvanized steel with Baltibond hybrid coating.
Typical Applications
- Industrial Cooling: Used in factories for process cooling.
- Air Conditioning (HVAC): Employed in large building complexes as part of a central chiller plant.
- Refrigeration: Used as a condenser in commercial refrigeration systems.
Cooling Performance
An open evaporative cooling tower has no fixed, single kW cooling capacity, as the actual capacity is entirely dependent on thermodynamic ambient conditions and system temperatures.
This model is rated for maximum flow rates up to 198 liters per second.
Under typical industrial or HVAC standard conditions, the nominal cooling capacity for this model ranges from approximately 1,200 kW to 2,100 kW.
Why Does Cooling Capacity Vary?
- Wet-bulb temperature (outside air): The cooler and drier the ambient air, the more water can evaporate and the higher the cooling capacity.
- Water temperatures: Performance strongly varies depending on the entering hot water temperature (e.g., 35°C) and exiting cold water temperature (e.g., 29°C).
- Airflow: According to BAC spec, the S15E 1018-10 LE actively moves 60.0 m³/s of air through three integrated 11.0 kW axial fan motors.
If fan speed is reduced by variable frequency drive (for example, during night operation or in winter), cooling capacity decreases proportionally.
- Approach: This is the most important thermodynamic limit. It represents the difference between the desired cold water temperature and the physical wet-bulb temperature. The closer the cold water approaches the wet-bulb temperature (smaller approach), the less kW capacity the tower provides.
Technical Data:
Fan & Air Data
- Airflow: 60.0 m³/s (induced draft)
- Fan Motors: 3 x 11.0 kW (axial fans)
- Technology: Integrated belt drive
- Water flow rate: 198 l/s
Hydraulic Connections
- Water inlet (Fluid Inlet): 1 x DN 250 (nominal diameter 250 mm)
- Water outlet (Fluid Outlet): 1 x DN 300 (nominal diameter 300 mm)
- Make-up Water Connection: 1 x DN 40 (ND 40 mm)
- Overflow / Drain: DN 80 (ND 80 mm) / DN 50 (ND 50 mm)
Oglas je bil avtomatsko preveden. Možne so napake pri prevodu.
Ponudnik
Opomba: Brezplačno se registrirajte ali prijavite, za dostop do vseh informacij.
Nazadnje na spletu: prejšnji teden
Registriran od: 2008
560 Oglasi na spletu
Pošlji povpraševanje
Telefon & Faks
+49 2862 ... oglasi
Ti oglasi bi vas prav tako lahko zanimali.
Mali oglas
Łęczna
812 km
Hladilna/topilna črpalka
New Сhiller / Heat pumpBlue Box 16/18 kW | With warranty
New Сhiller / Heat pumpBlue Box 16/18 kW | With warranty
Mali oglas
Niedźwiedź
539 km
Kompresorska enota
BITZER4NCS-12.2Y-40-40P (x4)
BITZER4NCS-12.2Y-40-40P (x4)
Mali oglas
Niedźwiedź
539 km
Kondenzator
GüntnerGVH 090.2A/2x5-N(D)
GüntnerGVH 090.2A/2x5-N(D)
Mali oglas
Romunija
653 km
Engel DUO 3550/400 pico
EngelDUO 3550/400 pico
EngelDUO 3550/400 pico
Mali oglas
Hillegom
1.019 km
Susen hladilnik
CaberoGCHSD089MB/X7S-40 Y V
CaberoGCHSD089MB/X7S-40 Y V
Mali oglas
Lanaken
867 km
Ploščni izmenjevalnik toplote
SondexSF160
SondexSF160
Mali oglas
Enschede
898 km
Stroj za brizganje
ENGELE-VICTORY 765H/170W/400 COMBI
ENGELE-VICTORY 765H/170W/400 COMBI
Mali oglas
Niedźwiedź
539 km
Suhi hladilnik
CaberoS-GC/DED 095 KA/2X4E
CaberoS-GC/DED 095 KA/2X4E
Mali oglas
Ecquevilly
1.028 km
Hladilna skupina
Copeland EmersonZXLE 50
Copeland EmersonZXLE 50
Dražba
Dražba zaključena
Baden-Württemberg
545 km
Stroj za erodiranje žice
MITSUBISHIFA 10S Advance
MITSUBISHIFA 10S Advance
Vaš oglas je bil uspešno izbrisan
Prišlo je do napake