Elektrarna za soproizvodnjo toplote in električne energijeagriKomp GmbH
BGA/NGA168
Elektrarna za soproizvodnjo toplote in električne energije
agriKomp GmbH
BGA/NGA168
Leto izdelave
2024
Stanje
Novo
Lokacija
Merkendorf 

Prikaži slike
Prikaži karto
Podatki o stroju
- Proizvajalec:
- agriKomp GmbH
- Model:
- BGA/NGA168
- Leto izdelave:
- 2024
- Stanje:
- novo
- funkcionalnost:
- popolnoma funkcionalen
Cena in lokacija
- Lokacija:
- Energiepark 2, 91732 Merkendorf, DE
Klic
Tehnične podrobnosti
- Moč:
- 350 kW (475,87 KM)
Podrobnosti ponudbe
- ID ponudbe:
- A16761621
- Nazadnje posodobljeno:
- dne 09.09.2024
Opis
Compact, highly efficient combined heat and power (CHP) unit featuring a state-of-the-art SCANIA V8 cylinder, lean-burn turbocharged 4-stroke gas Otto engine. The genset, gas pressure regulation line, and integrated mixture and engine water cooling circuits are mounted on a base frame for the generation of electricity and heat with a high-quality synchronous generator (3-phase, 400V, 50Hz) for grid-parallel operation. Optimized heat extraction is achieved via a plate heat exchanger for heating water/process heat with a supply/return temperature level of 85°C / 70°C.
OPTIONAL: Equipped with a catalytic converter (optional SCR system) for low-emission operation compliant with the MCP Directive (EU) and 44th BImSchV (DE).
TECHNICAL DATA
GENSET /CHP – Biogas 50% CH4
Electrical output at cos φ=1: 350 kWel
Electrical efficiency: 41.4 %
Thermal output (engine) at 180°C exhaust temperature: 334 kWth
Power ratio el/th: 1.05
Engine type: V8
Displacement: 16 liters
Firing thermal input – 100% load: 845 kW
Gas consumption at 50% CH4: 169.1 Nm³/h
Dimensions (L x W x H, meters): 4.1 x 1.5 x 2.1
Dwjdpfx Aget Uu Ezo Njc
Weight (dry): 4,500 kg
The CHP unit features a control cabinet with a display visualizing all relevant operating parameters, including a DSL modem for remote maintenance and external monitoring, as well as an interface for balancing energy connection to the E2M energy control system. Delivery includes a grid starter to provide optimum cranking speed, as well as a gas detector, smoke detector, emergency stop switch, and visual/audible alarm (strobe light/horn).
All piping is constructed of stainless steel (V2A) and insulated where required.
To ensure the engines remain at operating temperature, the installed heat pumps are programmed to start in a predetermined cycle to maintain the desired temperature.
An automatic gas shut-off valve for installation outside the CHP installation room is not included in the delivery scope.
The CHP complies with the medium-voltage directive VDE-AR-N 4110:2018-11.
An automatic gas shut-off valve for installation outside the CHP room, as well as all operating fluids, are not included in the delivery scope.
Alternatively, the CHP can also be delivered in a container.
The entire genset is also available in a natural gas configuration.
Oglas je bil preveden samodejno, zaradi česar je morda prišlo do napak pri prevodu.
OPTIONAL: Equipped with a catalytic converter (optional SCR system) for low-emission operation compliant with the MCP Directive (EU) and 44th BImSchV (DE).
TECHNICAL DATA
GENSET /CHP – Biogas 50% CH4
Electrical output at cos φ=1: 350 kWel
Electrical efficiency: 41.4 %
Thermal output (engine) at 180°C exhaust temperature: 334 kWth
Power ratio el/th: 1.05
Engine type: V8
Displacement: 16 liters
Firing thermal input – 100% load: 845 kW
Gas consumption at 50% CH4: 169.1 Nm³/h
Dimensions (L x W x H, meters): 4.1 x 1.5 x 2.1
Dwjdpfx Aget Uu Ezo Njc
Weight (dry): 4,500 kg
The CHP unit features a control cabinet with a display visualizing all relevant operating parameters, including a DSL modem for remote maintenance and external monitoring, as well as an interface for balancing energy connection to the E2M energy control system. Delivery includes a grid starter to provide optimum cranking speed, as well as a gas detector, smoke detector, emergency stop switch, and visual/audible alarm (strobe light/horn).
All piping is constructed of stainless steel (V2A) and insulated where required.
To ensure the engines remain at operating temperature, the installed heat pumps are programmed to start in a predetermined cycle to maintain the desired temperature.
An automatic gas shut-off valve for installation outside the CHP installation room is not included in the delivery scope.
The CHP complies with the medium-voltage directive VDE-AR-N 4110:2018-11.
An automatic gas shut-off valve for installation outside the CHP room, as well as all operating fluids, are not included in the delivery scope.
Alternatively, the CHP can also be delivered in a container.
The entire genset is also available in a natural gas configuration.
Oglas je bil preveden samodejno, zaradi česar je morda prišlo do napak pri prevodu.
Ponudnik
Opomba: Brezplačno se registrirajte ali prijavite, za dostop do vseh informacij.
Registriran od: 2021
Pošlji zahtevo
Telefon & Faks
+49 9826 ... oglasi
Vaš oglas je bil uspešno izbrisan
Prišlo je do napake