Klimatska omara z vlago, 100 litrov
Weiss WKL 100/40 -40...+180°C

Stanje
Rabljeno
Lokacija
Borken Nemčija
Klimatska omara z vlago, 100 litrov Weiss WKL 100/40 -40...+180°C
Klimatska omara z vlago, 100 litrov Weiss WKL 100/40 -40...+180°C
Klimatska omara z vlago, 100 litrov Weiss WKL 100/40 -40...+180°C
Klimatska omara z vlago, 100 litrov Weiss WKL 100/40 -40...+180°C
Klimatska omara z vlago, 100 litrov Weiss WKL 100/40 -40...+180°C
Klimatska omara z vlago, 100 litrov Weiss WKL 100/40 -40...+180°C
more Images
Weiss WKL 100/40 -40...+180°C
Weiss WKL 100/40 -40...+180°C
Weiss WKL 100/40 -40...+180°C
Weiss WKL 100/40 -40...+180°C
Weiss WKL 100/40 -40...+180°C
Weiss WKL 100/40 -40...+180°C
Prikaži slike
Prikaži karto

Podatki o stroju

Opis stroja:
Klimatska omara z vlago, 100 litrov
Proizvajalec:
Weiss
Model:
WKL 100/40 -40...+180°C
Stanje:
zelo dobro (rabljeno)

Cena in lokacija

Lokacija:
Einsteinstraße 8a, 46325 Borken, DE Nemčija
Klic

Prodaja strojev

Ste našli novo napravo? Zdaj staro pretvorite v denar.
Ste našli novo napravo? Zdaj staro pretvorite v denar. Dosežite najboljšo ceno prek Machineseeker.
Več o prodaji strojev

Podrobnosti ponudbe

ID ponudbe:
A20124430
Št. reference:
24814
Nazadnje posodobljeno:
dne 02.10.2025

Opis

Type: WKL 100/40
Climatic Test Chamber, Air-Cooled
with Humidity, -40 to +180°C

Technical Data for Temperature Testing:
Temperature range: -40 to +180°C
Temperature stability at equilibrium:
Temporal temperature fluctuation (center of usable space): ±0.3 to ±1 K
Spatial temperature deviation: ±0.5 to ±2 K
Temperature change rate:
Heating: 3.5 K/min
Cooling: 5 K/min
Heat compensation: max. 1100 W

Technical Data for Climatic Testing:
Humidification System:
Reservoir capacity: approx. 13 l
Water quality: Deionized
pH: 6 – 7
Conductivity: max. 20 μS/cm
Water consumption at constant +40°C, 92 % r.h.: 2 l / 24 h
Fedpsxhf Ersfx Ah Degh
Temperature range: +10 to +95°C
Humidity range: 10 to 98 % r.h.
Temperature and humidity stability (at equilibrium):
Temporal temperature fluctuation (center of usable space): ±0.3 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 K
Temporal humidity fluctuation (center of usable space): ±1 to ±3 % r.h.

Mechanical Load Data:
Maximum load on chamber floor: 25 kg
Per shelf: 10 kg
Total shelf load: 50 kg
Cable port: 50 mm diameter
Interfaces: Ethernet (RJ45), USB

Operational Data:
Test chamber lighting: Halogen bulb 24V, 50W
Nominal voltage: 1/N / PE AC 230 V ± 10 % 50 Hz
Nominal power: 3.0 kW
Nominal current: 13.0 A
Site-side fuse: 16A slow-blow
Protection rating:
Control cabinet: IP 22; Control panel: IP 54

Heat Emission (air-cooled chambers):
Max. heat emission to environment: 2000 W

Noise Measurement:
Sound pressure level—free field measurement at 1 m distance, 1.6 m height: approx. 56 dB(A)

Test Chamber Volume: approx. 100 liters
Weight: 190 kg
Refrigerant: R404A

For your safety as the buyer, please note the following information:
The following steps are carried out in advance on all chambers offered:
1. Function check and replacement of necessary components
2. If required, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.

Condition: used
Scope of delivery: (See photo)
(Specifications are subject to change; errors and omissions excepted!)
For further questions, feel free to contact us by phone.

Oglas je bil preveden samodejno, zaradi česar je morda prišlo do napak pri prevodu.

Ponudnik

Nazadnje na spletu: Včeraj

Registriran od: 2012

599 Oglasi na spletu

Trustseal Icon
Klic

Pošlji zahtevo

Državaus 
Nemčija
Avstrija
Švica
Združene države Amerike
Združeno kraljestvo
Francija
Belgija
Španija
Mehika
Italija
Nizozemska
Poljska
Ruska federacija
Belorusija (Beloruska republika)
Ukrajina
Estonija
Turčija
Nova Zelandija
Irska
Češka republika
Danska
Finska
Švedska
Norveška
Luksemburg
Grčija
Litva
Latvija
Islandija
Portugalska
Brazilija
Venezuela
Argentina
Madžarska
Slovaška
Romunija
Moldavija
Slovenija
Srbija
Črna gora
Albanija
Hrvaška
Bolgarija
Severna Makedonija
Bosna in Hercegovina
Izrael
Egipt
Maroko
Indija
Indonezija
Južna Koreja
Japonska
Tajska
Malezija
Vietnam
China
Tajvan
Iran
Bangladeš
Afganistan
Opomba: Vaše povpraševanje bo posredovano vsem prodajalcem v kategoriji strojev. S tem lahko prejmete zelo veliko ponudb.
Zahteve ni bilo mogoče poslati. Prosimo, poskusite znova kasneje.

Telefon & Faks

+49 2861 ... oglasi