HPLC Waters
The system consists of the following modules and components:
HPLC Waters Binary Solvent Manager
HPLC Waters Auxiliary Solvent Manager
HPLC Waters HDX Manager
HPLC Waters PAL System
HPLC Waters Leap
Synapt HDMS Mass Spectrometer
HPLC Waters Binary Solvent Manager
Klsdpfx Aevcnpaobxsu
Flow Control Modules
Flow rate from 0.20 to 5.00 µl/min
Solvents are mixed in the T-piece outlet of the flow control module.
Auxiliary Solvent Manager
Flow rates from 0.10 to 5.00 µl/min
Flow Control Module
Flow from 0.20 to 5.00 µl/min
Sample Manager
The sample manager injects samples drawn from microtiter plates or vials into the chromatographic flow path.
In maximum throughput mode, the sample manager can perform an injection in approximately 45 seconds, including a single standard wash, or in less than 60 seconds, including a double standard wash.
The sample manager accepts plates with a standard footprint, 5.03 $0.02 in x 3.365 $0.02 in, compliant with SBS/ANSI plates (maximum height of 2.2 in, including lids).
The sample manager can store samples at any temperature between 4 and 40 °C (39 and 104 °F) under ambient conditions of 25 °C (77 °F) or lower.
Heater and Capture Module
Inner diameter up to 300 micrometers and a length of 250 mm
Temperatures from 5 °C (9 °F) above ambient up to 65 °C (149 °F).
The column base can be pivoted outwards to any position between 0° and 180°.
In the 0° position “Home”, the column base is directly above the sample manager and can be connected to an optional optical detector.
In the 180° position “away”, the analytical column can be connected to a mass spectrometer (on the right side of the system).
The Synapt G2 is a Q-TOF-based mass spectrometer with an additional ion mobility cell, which enables orthogonal separation of ions based on their shape and conformation.
Equipped with an intermediate quadrupole (8k), this highly versatile instrument can be used solely for peptide identification (LC-MSE data-independent acquisition), as well as for denaturing and native MS analysis.
Documents & Downloads
Data sheet: Operating Manual
Condition: used
Scope of supply: (see image)
(Changes and errors in the technical data, information subject to change!)
For further questions, we will be happy to assist you by phone.
Oglas je bil avtomatsko preveden. Možne so napake pri prevodu.
The system consists of the following modules and components:
HPLC Waters Binary Solvent Manager
HPLC Waters Auxiliary Solvent Manager
HPLC Waters HDX Manager
HPLC Waters PAL System
HPLC Waters Leap
Synapt HDMS Mass Spectrometer
HPLC Waters Binary Solvent Manager
Klsdpfx Aevcnpaobxsu
Flow Control Modules
Flow rate from 0.20 to 5.00 µl/min
Solvents are mixed in the T-piece outlet of the flow control module.
Auxiliary Solvent Manager
Flow rates from 0.10 to 5.00 µl/min
Flow Control Module
Flow from 0.20 to 5.00 µl/min
Sample Manager
The sample manager injects samples drawn from microtiter plates or vials into the chromatographic flow path.
In maximum throughput mode, the sample manager can perform an injection in approximately 45 seconds, including a single standard wash, or in less than 60 seconds, including a double standard wash.
The sample manager accepts plates with a standard footprint, 5.03 $0.02 in x 3.365 $0.02 in, compliant with SBS/ANSI plates (maximum height of 2.2 in, including lids).
The sample manager can store samples at any temperature between 4 and 40 °C (39 and 104 °F) under ambient conditions of 25 °C (77 °F) or lower.
Heater and Capture Module
Inner diameter up to 300 micrometers and a length of 250 mm
Temperatures from 5 °C (9 °F) above ambient up to 65 °C (149 °F).
The column base can be pivoted outwards to any position between 0° and 180°.
In the 0° position “Home”, the column base is directly above the sample manager and can be connected to an optional optical detector.
In the 180° position “away”, the analytical column can be connected to a mass spectrometer (on the right side of the system).
The Synapt G2 is a Q-TOF-based mass spectrometer with an additional ion mobility cell, which enables orthogonal separation of ions based on their shape and conformation.
Equipped with an intermediate quadrupole (8k), this highly versatile instrument can be used solely for peptide identification (LC-MSE data-independent acquisition), as well as for denaturing and native MS analysis.
Documents & Downloads
Data sheet: Operating Manual
Condition: used
Scope of supply: (see image)
(Changes and errors in the technical data, information subject to change!)
For further questions, we will be happy to assist you by phone.
Oglas je bil avtomatsko preveden. Možne so napake pri prevodu.
Pošlji povpraševanje
Telefon & Faks
+49 2861 ... oglasi
Ti oglasi bi vas prav tako lahko zanimali.
Mali oglas
Wald
484 km
Spektrometer
Varian640-IR FT-IR
Varian640-IR FT-IR
Mali oglas
Krotoszyn
643 km
Industrijski parni kotel
Loos Bosch GroupU-ND 800
Loos Bosch GroupU-ND 800
Mali oglas
Ybbs an der Donau
225 km
Spektrometer FTIR - NICOLET IS20
ThermoFisher ScientificNICOLET IS20
ThermoFisher ScientificNICOLET IS20
Mali oglas
Hadımköy
1.284 km
Rotacijski predorski pralni stroj
INTERSONIKRT-540
INTERSONIKRT-540
Mali oglas
Erlangen
486 km
7,5 kW vijačni kompresor s sušilnikom
KaeserSM 13 T
KaeserSM 13 T
Mali oglas
Dn10 4Es
1.392 km
Enojni odlagalec
AFTmini depositor
AFTmini depositor
Mali oglas
Łabuńki Pierwsze
796 km
Vijačni kompresor
Atlas CopcoG11FF
Atlas CopcoG11FF
Mali oglas
Velen
867 km
Plazemski rezalnik
HBMCUT 60
HBMCUT 60
Mali oglas
Malawa
681 km
Pekarska peč + nakladalni sistem
MiweTHERMO EXPRESS + ATHLET
MiweTHERMO EXPRESS + ATHLET
Vaš oglas je bil uspešno izbrisan
Prišlo je do napake