Klimatska komora optimizirana za testiranje baterijVötsch
VCZ 60006/-1/S -60 bis +160
Klimatska komora optimizirana za testiranje baterij
Vötsch
VCZ 60006/-1/S -60 bis +160
Stanje
Rabljeno
Lokacija
Borken 

Prikaži slike
Prikaži karto
Podatki o stroju
- Oznaka stroja:
- Klimatska komora optimizirana za testiranje baterij
- Proizvajalec:
- Vötsch
- Stanje:
- dober (rabljeno)
Cena in lokacija
- Lokacija:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Pokliči
Podrobnosti ponudbe
- ID oglasa:
- A21671963
- Referenčna številka:
- 25129
- Posodobitev:
- nazadnje dne 10.04.2026
Opis
Vötsch
System used for battery testing
Inert gas connection and pressure equalization flap
+Fresh air purging approx. 100 m³/h
Water-cooled
Type: VCZ 60006/-1/S
Large-scale climatic test chamber for temperature and climate testing
Test chamber volume: approx. 7.5 m³
Internal dimensions: approx. height 1,480 mm x width 2,470 mm x depth 2,050 mm
External dimensions: approx. height 2,400 mm x width 3,200 mm x depth 4,270 mm
Test chamber floor load capacity: 3,000 kg/m²
Temperature test data:
Temperature range: -40°C to +160°C
Heating rate within -40 to +100°C: approx. 1 K/min
Cooling rate within +100 to -40°C: approx. 1.5 K/min
Heat compensation to -40°C / +20°C: 8,000 W
Climatic test data:
Temperature range: +10 to +80°C
Humidity range: 10 to 90% r.h.
Dew point range: +5 to +77.4°C
Temperature deviation over time: +/- 0.1 to +/- 0.5 K
Humidity deviation over time: +/- 3 to +/- 5% r.h.
Operating data:
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal power: 25 kW
Nominal current: 41 A
Weight: 3,500 kg
Ljdpsyzpa Nsfx Al Nork
Refrigerant R-404A / R-23: 6.5 kg & 3.2 kg
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. Leak test with certificate
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (see image)
(Technical data, specifications and subject to change and errors!)
Further questions can be answered for you by phone.
Oglas je bil avtomatsko preveden. Možne so napake pri prevodu.
System used for battery testing
Inert gas connection and pressure equalization flap
+Fresh air purging approx. 100 m³/h
Water-cooled
Type: VCZ 60006/-1/S
Large-scale climatic test chamber for temperature and climate testing
Test chamber volume: approx. 7.5 m³
Internal dimensions: approx. height 1,480 mm x width 2,470 mm x depth 2,050 mm
External dimensions: approx. height 2,400 mm x width 3,200 mm x depth 4,270 mm
Test chamber floor load capacity: 3,000 kg/m²
Temperature test data:
Temperature range: -40°C to +160°C
Heating rate within -40 to +100°C: approx. 1 K/min
Cooling rate within +100 to -40°C: approx. 1.5 K/min
Heat compensation to -40°C / +20°C: 8,000 W
Climatic test data:
Temperature range: +10 to +80°C
Humidity range: 10 to 90% r.h.
Dew point range: +5 to +77.4°C
Temperature deviation over time: +/- 0.1 to +/- 0.5 K
Humidity deviation over time: +/- 3 to +/- 5% r.h.
Operating data:
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal power: 25 kW
Nominal current: 41 A
Weight: 3,500 kg
Ljdpsyzpa Nsfx Al Nork
Refrigerant R-404A / R-23: 6.5 kg & 3.2 kg
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. Leak test with certificate
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (see image)
(Technical data, specifications and subject to change and errors!)
Further questions can be answered for you by phone.
Oglas je bil avtomatsko preveden. Možne so napake pri prevodu.
Pošlji povpraševanje
Telefon & Faks
+49 2861 ... oglasi
Vaš oglas je bil uspešno izbrisan
Prišlo je do napake