Temperaturna preskusna komora 335 litrovVötsch
-70°C bis +180°C VTS 7034-5
Temperaturna preskusna komora 335 litrov
Vötsch
-70°C bis +180°C VTS 7034-5
Stanje
Rabljeno
Lokacija
Borken 

Prikaži slike
Prikaži karto
Podatki o stroju
- Oznaka stroja:
- Temperaturna preskusna komora 335 litrov
- Proizvajalec:
- Vötsch
- Stanje:
- zelo dobro (rabljeno)
Cena in lokacija
- Lokacija:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Pokliči
Podrobnosti ponudbe
- ID oglasa:
- A20451980
- Referenčna številka:
- 24866
- Posodobitev:
- nazadnje dne 04.11.2025
Opis
Type: VCS 7034-5
Climate Test Chamber, Water-Cooled
Test Chamber Volume: 335 liters
Performance for Temperature Testing:
Temperature range: -70 to +180°C
Temporal temperature deviation: K ±0.1 to ±0.5
Spatial temperature deviation: K ±0.5 to ±2.0
Temperature gradient: 1 to 4
Change rate:
Cooling: 3.5 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration values: +23°C and +80°C
Performance for Climatic Testing:
Temperature range: +10°C to +95°C
Temporal temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Temporal humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration values: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
1 port Ø approx. 50 mm, left side
2 ports Ø approx. 125 mm, left side
1 port Ø approx. 125 mm, right side
Electrical connection: 3/N/PE AC, 400 V ±10%, 50 Hz
Nominal power: 10 kW
Nominal current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R404A / R-23
For your safety as the buyer, please note the following:
The following procedures are carried out in advance on all our offered chambers:
1. Functional check and replacement of necessary components
2. If required, refill with legally compliant refrigerant
3. Leak test with certificate
Dusdpfx Adoxufype Aop
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (See image)
(Specifications are subject to change and errors excepted!)
If you have further questions, feel free to contact us by phone.
Oglas je bil avtomatsko preveden. Možne so napake pri prevodu.
Climate Test Chamber, Water-Cooled
Test Chamber Volume: 335 liters
Performance for Temperature Testing:
Temperature range: -70 to +180°C
Temporal temperature deviation: K ±0.1 to ±0.5
Spatial temperature deviation: K ±0.5 to ±2.0
Temperature gradient: 1 to 4
Change rate:
Cooling: 3.5 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration values: +23°C and +80°C
Performance for Climatic Testing:
Temperature range: +10°C to +95°C
Temporal temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Temporal humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration values: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
1 port Ø approx. 50 mm, left side
2 ports Ø approx. 125 mm, left side
1 port Ø approx. 125 mm, right side
Electrical connection: 3/N/PE AC, 400 V ±10%, 50 Hz
Nominal power: 10 kW
Nominal current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R404A / R-23
For your safety as the buyer, please note the following:
The following procedures are carried out in advance on all our offered chambers:
1. Functional check and replacement of necessary components
2. If required, refill with legally compliant refrigerant
3. Leak test with certificate
Dusdpfx Adoxufype Aop
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (See image)
(Specifications are subject to change and errors excepted!)
If you have further questions, feel free to contact us by phone.
Oglas je bil avtomatsko preveden. Možne so napake pri prevodu.
Pošlji povpraševanje
Telefon & Faks
+49 2861 ... oglasi
Ti oglasi bi vas prav tako lahko zanimali.
Mali oglas
Borken
868 km
Temperaturna preskusna komora 335 litrov
Vötsch-70°C bis +180°C VTS 7034-5
Vötsch-70°C bis +180°C VTS 7034-5
Mali oglas
Borken
868 km
Klimatska preizkusna komora 800 L, -55°C do +180°C
WeissClimeEvent C/800/55a/25/S 25K/min
WeissClimeEvent C/800/55a/25/S 25K/min
Mali oglas
Borken
868 km
Temperaturna preskusna komora 335 litrov
VötschVTS 7034-5 -70°C bis +180°C
VötschVTS 7034-5 -70°C bis +180°C
Mali oglas
Borken
868 km
Weissova temperaturna omara -72°C - +180°C
Weiss Temperaturschrank -72°C - +180°CWT3-340/70 335 Liter Luftgekühlt
Weiss Temperaturschrank -72°C - +180°CWT3-340/70 335 Liter Luftgekühlt
Mali oglas
Borken
868 km
Temperaturna preizkusna komora 335 litrov
Weiss Technik TempEventT/340/40/3/S -40°C bis +180°C
Weiss Technik TempEventT/340/40/3/S -40°C bis +180°C
Vaš oglas je bil uspešno izbrisan
Prišlo je do napake