Opis
Dionex / ThermoFisher
FLM:
Temperature range: 5–70 °C (max. 15 °C below ambient temperature)
Temperature accuracy: ±0.5 °C
Temperature stability: ±0.1 °C
Temperature precision: ±0.1 °C
Column capacity: Up to 3 columns, max. 30 cm length
Heating time: From 20 to 50 °C in less than 25 min
(at 23 °C ambient temperature, ±0.5 °C)
Cooling time: From 50 to 20 °C in less than 35 min
(at 23 °C ambient temperature, ±0.5 °C)
Control: All functions software-controlled via USB 1.1
I/O interfaces: 2 digital inputs, 2 programmable relay outputs
Iedpsxtb Efsfx Ah Aoik
Column identification: Electronic identification system for up to 3 columns
Switching valves: 1 or 2 thermostated microvalves with low dispersion
(10 ports or 6 ports)
Flow distributor: Nano-, capillary, or thermostated micro-flow distributor with
flow distributor identification system
Flow control: Electronically controlled and actively balanced flow splitter,
independent of solvent composition and back pressure
Column flow rate range: 50 nL/min to 2.5 mL/min using a predefined splitter and
active flow control
Selectable flow rate range: 50 nL/min to 1000 nL/min (using a nano-LC splitter)
0.5 μL/min to 10 μL/min (with a capillary LC splitter)
10 μL/min to 160 μL/min (with a micro-LC splitter)
Gradient delay time: Typically < 1.5 min at 200 nL/min to splitter outlet
Max. column pressure: 35 MPa (4900 psi)
Wetted materials: Quartz glass, stainless steel (1.4571, 316L), PEEK;
Waste line: PTFE, aluminum oxide (Al₂O₃)
Safety features: Humidity sensor, gas sensor, and leak sensor for the flow control valve
VWD
Optical design: Double-beam photometer (monochromator)
Multi-wavelength UV/VIS detector
Light source: VWD-3400RS: Deuterium lamp and tungsten lamp
Temperature control for both lamps
Wavelength range: 190 to 900 nm
Tungsten lamp recommended for wavelengths > 600 nm.
Noise:
At one wavelength:
Oglas je bil preveden samodejno, zaradi česar je morda prišlo do napak pri prevodu.
FLM:
Temperature range: 5–70 °C (max. 15 °C below ambient temperature)
Temperature accuracy: ±0.5 °C
Temperature stability: ±0.1 °C
Temperature precision: ±0.1 °C
Column capacity: Up to 3 columns, max. 30 cm length
Heating time: From 20 to 50 °C in less than 25 min
(at 23 °C ambient temperature, ±0.5 °C)
Cooling time: From 50 to 20 °C in less than 35 min
(at 23 °C ambient temperature, ±0.5 °C)
Control: All functions software-controlled via USB 1.1
I/O interfaces: 2 digital inputs, 2 programmable relay outputs
Iedpsxtb Efsfx Ah Aoik
Column identification: Electronic identification system for up to 3 columns
Switching valves: 1 or 2 thermostated microvalves with low dispersion
(10 ports or 6 ports)
Flow distributor: Nano-, capillary, or thermostated micro-flow distributor with
flow distributor identification system
Flow control: Electronically controlled and actively balanced flow splitter,
independent of solvent composition and back pressure
Column flow rate range: 50 nL/min to 2.5 mL/min using a predefined splitter and
active flow control
Selectable flow rate range: 50 nL/min to 1000 nL/min (using a nano-LC splitter)
0.5 μL/min to 10 μL/min (with a capillary LC splitter)
10 μL/min to 160 μL/min (with a micro-LC splitter)
Gradient delay time: Typically < 1.5 min at 200 nL/min to splitter outlet
Max. column pressure: 35 MPa (4900 psi)
Wetted materials: Quartz glass, stainless steel (1.4571, 316L), PEEK;
Waste line: PTFE, aluminum oxide (Al₂O₃)
Safety features: Humidity sensor, gas sensor, and leak sensor for the flow control valve
VWD
Optical design: Double-beam photometer (monochromator)
Multi-wavelength UV/VIS detector
Light source: VWD-3400RS: Deuterium lamp and tungsten lamp
Temperature control for both lamps
Wavelength range: 190 to 900 nm
Tungsten lamp recommended for wavelengths > 600 nm.
Noise:
At one wavelength:
Oglas je bil preveden samodejno, zaradi česar je morda prišlo do napak pri prevodu.
Ponudnik
Opomba: Brezplačno se registrirajte ali prijavite, za dostop do vseh informacij.
Registriran od: 2012
Pošlji zahtevo
Telefon & Faks
+49 2861 ... oglasi
Ti oglasi bi vas prav tako lahko zanimali.
Mali oglas
Győr
265 km
Sistem HPLC s programsko opremo - preberite!
Agilent1100
Agilent1100
Mali oglas
Duxford
1.264 km
Sistem HPLC Agilent Cary 1260 infinity
Agilent Cary1260 infinity
Agilent Cary1260 infinity
Mali oglas
Borken
868 km
Masni spektrometer (razpršilnik za rezervne dele)
SCIEXAPI 4000
SCIEXAPI 4000
Mali oglas
Marthalen
509 km
Namizna tehtnica
Mettler ToledoMB60S
Mettler ToledoMB60S
Vaš oglas je bil uspešno izbrisan
Prišlo je do napake