HPLCThermoFisher / Dionex
        UltiMate 3000    
 HPLC
ThermoFisher / Dionex
        UltiMate 3000    
                                                     Stalna cena brez DDV                                            
                                            10.000 €                                    
            Stanje        
            Rabljeno                    
            Lokacija        
                                                Borken                                            

 Prikaži slike            
 Prikaži karto            
Podatki o stroju
Cena in lokacija
                             Stalna cena brez DDV                    
                            10.000 €                    
- Lokacija:
-             Einsteinstraße 8a, 46325 Borken, DE                 
 Klic            
Podrobnosti ponudbe
- ID ponudbe:
- A20416260
- Št. reference:
- 24837
- Nazadnje posodobljeno:
- dne 30.10.2025
Opis
        Dionex / ThermoFisher
FLM:
Temperature range: 5–70 °C (max. 15 °C below ambient temperature)
Temperature accuracy: ±0.5 °C
Temperature stability: ±0.1 °C
Temperature precision: ±0.1 °C
Column capacity: Up to 3 columns, max. 30 cm length
Heating time: From 20 to 50 °C in less than 25 min
(at 23 °C ambient temperature, ±0.5 °C)
Cooling time: From 50 to 20 °C in less than 35 min
(at 23 °C ambient temperature, ±0.5 °C)
Control: All functions software-controlled via USB 1.1
I/O interfaces: 2 digital inputs, 2 programmable relay outputs
Column identification: Electronic identification system for up to 3 columns
Switching valves: 1 or 2 thermostated microvalves with low dispersion
(10 ports or 6 ports)
Flow distributor: Nano-, capillary, or thermostated micro-flow distributor with
flow distributor identification system
Flow control: Electronically controlled and actively balanced flow splitter,
independent of solvent composition and back pressure
Column flow rate range: 50 nL/min to 2.5 mL/min using a predefined splitter and
active flow control
Selectable flow rate range: 50 nL/min to 1000 nL/min (using a nano-LC splitter)
0.5 μL/min to 10 μL/min (with a capillary LC splitter)
10 μL/min to 160 μL/min (with a micro-LC splitter)
Gradient delay time: Typically < 1.5 min at 200 nL/min to splitter outlet
Max. column pressure: 35 MPa (4900 psi)
Wetted materials: Quartz glass, stainless steel (1.4571, 316L), PEEK;
Rcsdpfx Aoxtb Efshuoh
Waste line: PTFE, aluminum oxide (Al₂O₃)
Safety features: Humidity sensor, gas sensor, and leak sensor for the flow control valve
VWD
Optical design: Double-beam photometer (monochromator)
Multi-wavelength UV/VIS detector
Light source: VWD-3400RS: Deuterium lamp and tungsten lamp
Temperature control for both lamps
Wavelength range: 190 to 900 nm
Tungsten lamp recommended for wavelengths > 600 nm.
Noise:
At one wavelength:
Oglas je bil preveden samodejno, zaradi česar je morda prišlo do napak pri prevodu.
FLM:
Temperature range: 5–70 °C (max. 15 °C below ambient temperature)
Temperature accuracy: ±0.5 °C
Temperature stability: ±0.1 °C
Temperature precision: ±0.1 °C
Column capacity: Up to 3 columns, max. 30 cm length
Heating time: From 20 to 50 °C in less than 25 min
(at 23 °C ambient temperature, ±0.5 °C)
Cooling time: From 50 to 20 °C in less than 35 min
(at 23 °C ambient temperature, ±0.5 °C)
Control: All functions software-controlled via USB 1.1
I/O interfaces: 2 digital inputs, 2 programmable relay outputs
Column identification: Electronic identification system for up to 3 columns
Switching valves: 1 or 2 thermostated microvalves with low dispersion
(10 ports or 6 ports)
Flow distributor: Nano-, capillary, or thermostated micro-flow distributor with
flow distributor identification system
Flow control: Electronically controlled and actively balanced flow splitter,
independent of solvent composition and back pressure
Column flow rate range: 50 nL/min to 2.5 mL/min using a predefined splitter and
active flow control
Selectable flow rate range: 50 nL/min to 1000 nL/min (using a nano-LC splitter)
0.5 μL/min to 10 μL/min (with a capillary LC splitter)
10 μL/min to 160 μL/min (with a micro-LC splitter)
Gradient delay time: Typically < 1.5 min at 200 nL/min to splitter outlet
Max. column pressure: 35 MPa (4900 psi)
Wetted materials: Quartz glass, stainless steel (1.4571, 316L), PEEK;
Rcsdpfx Aoxtb Efshuoh
Waste line: PTFE, aluminum oxide (Al₂O₃)
Safety features: Humidity sensor, gas sensor, and leak sensor for the flow control valve
VWD
Optical design: Double-beam photometer (monochromator)
Multi-wavelength UV/VIS detector
Light source: VWD-3400RS: Deuterium lamp and tungsten lamp
Temperature control for both lamps
Wavelength range: 190 to 900 nm
Tungsten lamp recommended for wavelengths > 600 nm.
Noise:
At one wavelength: