Diferencialni toplotni kalorimeterPerkin Elmer
DSC 8000, N5340524
Diferencialni toplotni kalorimeter
Perkin Elmer
DSC 8000, N5340524
EXW Fiksna cena plus DDV
29.750 €
Stanje
Rabljeno
Lokacija
Dresden 

Prikaži slike
Prikaži karto
Podatki o stroju
- Oznaka stroja:
- Diferencialni toplotni kalorimeter
- Proizvajalec:
- Perkin Elmer
- Model:
- DSC 8000, N5340524
- Stanje:
- rabljeno
Cena in lokacija
EXW Fiksna cena plus DDV
29.750 €
- Lokacija:
- Heilbronner Str. 22, 01189 Dresden, Deutschland

Pokliči
Podrobnosti ponudbe
- ID oglasa:
- A21283042
- Referenčna številka:
- LW43630
- Posodobitev:
- nazadnje dne 20.02.2026
Opis
Perkin Elmer Instruments Differential Scanning Calorimeter with Cooling, DSC 8000, N5340524
Model: DSC8000
Type: N5340524
Condition: Used
General Information:
Double-furnace differential scanning calorimeter with power compensation, Perkin Elmer DSC 8000 with Intracooler 2, offering precise heat flow measurements from approx. –70 °C to 750 °C with high sensitivity and rapid thermal response.
General Instrument Specifications
DSC Type: Double furnace design (independent sample and reference furnaces)
Measurement Principle: Power compensation
Furnace Material: 90% platinum alloy
Temperature Sensors: Distributed platinum resistance thermometers
Temperature Performance
Standard Temperature Range: approx. –180 °C to 750 °C (with appropriate cooling accessories)
With Intracooler 2: approx. –70 °C to 750 °C
Minimum Temperature (Intracooler 2): approx. –80 °C
Heating Rate: 0.01 to 300 °C/min
Cooling Rate: 0.01 to 150 °C/min
Measurement Performance
Dynamic Range: ±800 mW (typical)
High sensitivity and fast response time thanks to low-mass furnace design
Outstanding baseline stability and temperature accuracy
Gas and Atmosphere Control
Two regulated gas lines with automatic switching
Typical purge gases: nitrogen, helium, argon
Supports high gas purity (up to 99.999%)
Interfaces and Connections
USB Ethernet (LAN)
Gas inlet connections
Connection for cooling unit
Mains power connection
Accessory ports (e.g. autosampler, high-pressure cell, UV/photocalorimeter module)
Interface for temperature calibration
Technical Data
3.15 AMP T (5 x 20 mm) 250 V
100–240 VAC 50/60 Hz
Maximum power 400 VA
Accessories
Cooling system PolyScience Intracooler 2
Norgren gas pressure regulator with gauges for external gas supply
96-position autosampler
High-pressure DSC cells, UV/photocalorimeter accessories
IEC power connector
Documentation
PolyScience Intracooler 2
Model: N5341746
P10N9E402E
Voltage: 240 IP-100
Hz/A/Ph: 50/7.5/1
Refrigerant: 350 g R-404A
Note on item condition:
Gsdpfx Afsyluicjwoua
Without software/PC
Oglas je bil avtomatsko preveden. Možne so napake pri prevodu.
Model: DSC8000
Type: N5340524
Condition: Used
General Information:
Double-furnace differential scanning calorimeter with power compensation, Perkin Elmer DSC 8000 with Intracooler 2, offering precise heat flow measurements from approx. –70 °C to 750 °C with high sensitivity and rapid thermal response.
General Instrument Specifications
DSC Type: Double furnace design (independent sample and reference furnaces)
Measurement Principle: Power compensation
Furnace Material: 90% platinum alloy
Temperature Sensors: Distributed platinum resistance thermometers
Temperature Performance
Standard Temperature Range: approx. –180 °C to 750 °C (with appropriate cooling accessories)
With Intracooler 2: approx. –70 °C to 750 °C
Minimum Temperature (Intracooler 2): approx. –80 °C
Heating Rate: 0.01 to 300 °C/min
Cooling Rate: 0.01 to 150 °C/min
Measurement Performance
Dynamic Range: ±800 mW (typical)
High sensitivity and fast response time thanks to low-mass furnace design
Outstanding baseline stability and temperature accuracy
Gas and Atmosphere Control
Two regulated gas lines with automatic switching
Typical purge gases: nitrogen, helium, argon
Supports high gas purity (up to 99.999%)
Interfaces and Connections
USB Ethernet (LAN)
Gas inlet connections
Connection for cooling unit
Mains power connection
Accessory ports (e.g. autosampler, high-pressure cell, UV/photocalorimeter module)
Interface for temperature calibration
Technical Data
3.15 AMP T (5 x 20 mm) 250 V
100–240 VAC 50/60 Hz
Maximum power 400 VA
Accessories
Cooling system PolyScience Intracooler 2
Norgren gas pressure regulator with gauges for external gas supply
96-position autosampler
High-pressure DSC cells, UV/photocalorimeter accessories
IEC power connector
Documentation
PolyScience Intracooler 2
Model: N5341746
P10N9E402E
Voltage: 240 IP-100
Hz/A/Ph: 50/7.5/1
Refrigerant: 350 g R-404A
Note on item condition:
Gsdpfx Afsyluicjwoua
Without software/PC
Oglas je bil avtomatsko preveden. Možne so napake pri prevodu.
Ponudnik
Opomba: Brezplačno se registrirajte ali prijavite, za dostop do vseh informacij.
Registriran od: 2014
97 Oglasi na spletu
Pošlji povpraševanje
Telefon & Faks
+49 351 8... oglasi
Ti oglasi bi vas prav tako lahko zanimali.
Mali oglas
Hannover
795 km
Namizni sistem Metal Studio II
Desktop MetalStudio System II
Desktop MetalStudio System II
Mali oglas
Borken
868 km
10°C do +250°C / 749 litrov
Memmert Universal - WärmeschrankUFP 800
Memmert Universal - WärmeschrankUFP 800
Mali oglas
Borken
868 km
Univerzalna preizkusna komora +20 °C do +300 °C
MemmertUF 450plus
MemmertUF 450plus
Mali oglas
Wald
484 km
Univerzalna peč / peč / toplotna komora
MemmertULP 600
MemmertULP 600
Mali oglas
Španija
653 km
DESKTOP METAL Metal Studio 2
DESKTOP METALMetal Studio 2
DESKTOP METALMetal Studio 2
Vaš oglas je bil uspešno izbrisan
Prišlo je do napake