Klimatska komora Memmert ICH 750Memmert
ICH 750
Klimatska komora Memmert ICH 750
Memmert
ICH 750
Stalna cena brez DDV
14.000 €
Leto izdelave
2022
Stanje
Rabljeno
Lokacija
Żychlin 

Prikaži slike
Prikaži karto
Podatki o stroju
- Opis stroja:
- Klimatska komora Memmert ICH 750
- Proizvajalec:
- Memmert
- Model:
- ICH 750
- Leto izdelave:
- 2022
- Stanje:
- skoraj kot novo (rabljeno)
Cena in lokacija
Stalna cena brez DDV
14.000 €
- Lokacija:
- ul Narutowicza 44-10, 99-320 Żychlin, PL
Klic
Podrobnosti ponudbe
- ID ponudbe:
- A19993820
- Nazadnje posodobljeno:
- dne 14.09.2025
Opis
Memmert ICH 750 Chamber from 2022, originally packaged and tested, like new condition, one-year spare parts warranty
Temperature
Temperature setting range:
-10 to +60 °C
Operating temperature range:
from -10°C to +60°C without humidity
(not suitable for long-term storage below zero; with continuous operation, glass doors may frost up)
Operating temperature range:
from +10°C to +60°C with humidity and/or light
Temperature setting accuracy:
0.1 °C
Temperature sensors:
2 Pt100 sensors, DIN class A in 4-wire configuration, mutually monitoring and assuming functions in case of failure
Humidity
Humidity supply:
distilled water supply from an external tank via self-priming pump
Iisdpfxoxcgh Re Ah Djh
Humidification:
humidification via steam generator
Humidity control:
active humidification and dehumidification, adjustable from 10–80% RH, with digital display for relative humidity – display resolution 0.1%, setpoint accuracy 0.5%
Control Technology
ControlCOCKPIT
TwinDISPLAY. Adaptive, multifunctional digital PID controller with microprocessor and two high-resolution color TFT displays.
Adjustable parameters:
temperature (°C or °F), fan speed, relative humidity, program time, time zones, summer/winter time
Language settings:
German, English, Spanish, French, Polish, Czech, Hungarian, Italian, Chinese
Timer:
digital countdown timer with target time setting, adjustable from 1 minute to 99 days
SetpointWAIT Function:
process time does not start until set temperature is reached
Calibration:
freely selectable three values for temperature/humidity and two for CO₂
Ventilation
Fan:
forced air circulation in the working chamber, adjustable from 10–100% in 10% increments
Communication
Data logging:
program is saved in case of power failure
Programming:
AtmoCONTROL software on USB stick for programming, managing, and transferring programs via Ethernet interface or USB port
Safety
Temperature control:
mechanical temperature limiter TB, safety class 1 according to DIN 12880, disconnects heating approx. 10 °C above nominal temperature
Temperature monitoring:
overtemperature/undertemperature monitor TWW, safety class 3.3, or adjustable temperature limiter TWB, safety class 2, selectable from the display
AutoSAFETY:
integrated overheating/undercooling protection system "ASF", automatically tracking setpoint within defined tolerance range, alarm if temperature is exceeded or falls below limits; in case of overtemperature heating is switched off, in case of undertemperature – compressor
Self-diagnostic system:
integrated error diagnostics for temperature and humidity control
Alarm:
visual and acoustic
Heating Concept
Air jacket:
air jacket heating system for gentle, uniform heating
Heating concept:
no sample drying caused by the cooling unit thanks to separation of heating jacket from chamber interior
Cooling:
energy-efficient cooling/heating system, CFC-free refrigerant R134A
Defrosting:
high-performance, automatic defrost system
Standard Equipment
Factory calibration certificate:
standard values +10°C and +37°C, 60% RH at +30°C
Oglas je bil preveden samodejno, zaradi česar je morda prišlo do napak pri prevodu.
Temperature
Temperature setting range:
-10 to +60 °C
Operating temperature range:
from -10°C to +60°C without humidity
(not suitable for long-term storage below zero; with continuous operation, glass doors may frost up)
Operating temperature range:
from +10°C to +60°C with humidity and/or light
Temperature setting accuracy:
0.1 °C
Temperature sensors:
2 Pt100 sensors, DIN class A in 4-wire configuration, mutually monitoring and assuming functions in case of failure
Humidity
Humidity supply:
distilled water supply from an external tank via self-priming pump
Iisdpfxoxcgh Re Ah Djh
Humidification:
humidification via steam generator
Humidity control:
active humidification and dehumidification, adjustable from 10–80% RH, with digital display for relative humidity – display resolution 0.1%, setpoint accuracy 0.5%
Control Technology
ControlCOCKPIT
TwinDISPLAY. Adaptive, multifunctional digital PID controller with microprocessor and two high-resolution color TFT displays.
Adjustable parameters:
temperature (°C or °F), fan speed, relative humidity, program time, time zones, summer/winter time
Language settings:
German, English, Spanish, French, Polish, Czech, Hungarian, Italian, Chinese
Timer:
digital countdown timer with target time setting, adjustable from 1 minute to 99 days
SetpointWAIT Function:
process time does not start until set temperature is reached
Calibration:
freely selectable three values for temperature/humidity and two for CO₂
Ventilation
Fan:
forced air circulation in the working chamber, adjustable from 10–100% in 10% increments
Communication
Data logging:
program is saved in case of power failure
Programming:
AtmoCONTROL software on USB stick for programming, managing, and transferring programs via Ethernet interface or USB port
Safety
Temperature control:
mechanical temperature limiter TB, safety class 1 according to DIN 12880, disconnects heating approx. 10 °C above nominal temperature
Temperature monitoring:
overtemperature/undertemperature monitor TWW, safety class 3.3, or adjustable temperature limiter TWB, safety class 2, selectable from the display
AutoSAFETY:
integrated overheating/undercooling protection system "ASF", automatically tracking setpoint within defined tolerance range, alarm if temperature is exceeded or falls below limits; in case of overtemperature heating is switched off, in case of undertemperature – compressor
Self-diagnostic system:
integrated error diagnostics for temperature and humidity control
Alarm:
visual and acoustic
Heating Concept
Air jacket:
air jacket heating system for gentle, uniform heating
Heating concept:
no sample drying caused by the cooling unit thanks to separation of heating jacket from chamber interior
Cooling:
energy-efficient cooling/heating system, CFC-free refrigerant R134A
Defrosting:
high-performance, automatic defrost system
Standard Equipment
Factory calibration certificate:
standard values +10°C and +37°C, 60% RH at +30°C
Oglas je bil preveden samodejno, zaradi česar je morda prišlo do napak pri prevodu.
Ponudnik
Opomba: Brezplačno se registrirajte ali prijavite, za dostop do vseh informacij.
Pošlji zahtevo
Telefon & Faks
+48 793 1... oglasi
Vaš oglas je bil uspešno izbrisan
Prišlo je do napake