GBS Prüfpuls rev3 Pulse Generator for Long-Term Insulation Tests
The Prüfpuls setup is designed for long-duration insulation tests on test objects with capacitance up to 6 nF.
Inverter for High Voltage Test Transformer
· Internal sine wave generator: 50-200Hz.
· Pulse width modulation at 16-24kHz of the sine wave via full bridge.
· Inverter voltage adjustable 0-600V, Imax=2.6A, maximum power 1.3kW
· Pulse current limitation 110A (cut-off threshold)
Cgjdpfx Afou Egz Rsnop
Pulse Transformer – Control
· Control via full bridge
· Full bridge power supply adjustable 0-1000V, max. 1.3A
· Pulse current limitation 100A (cut-off threshold)
· Pulse width 20-120μs, nominal 94μs, adjustable
· 2 selectable series inductances 150μH, 300μH to adapt the pulse width or rise times to the load capacitance and voltage
· Pulse repetition frequency 0.1 – 2.5 kHz, adjustable
· Polarity: adjustable positive, negative or alternating depending on the polarity of the sine signal
· Cosine-shaped pulse at transformer output
Pulse Transformer Cascade
· Output transformers in 5-stage cascaded configuration
· Overall turns ratio selectable via taps as 1:7.7, 1:10 or 1:15
· Maximum output voltage 15kV at the following possible load capacitances: * 6nF with a pulse width of 73μs at a repetition frequency of 2.5kHz * 10nF with a pulse width of 103μs at a repetition frequency of 1.25kHz
· Voltage divider 1:1000 in parallel
· Overvoltage limitation at approx. 20-23 kV via parallel spark gaps
· Thermistor for overtemperature detection in the first transformer stage
· Earth-side current measurement socket 100 mV/A
Qgqsbmp2
Breakdown Detection, Testing
· If the maximum bridge currents for transformer controls or for the bridge power supplies are exceeded, the high voltage is switched off
· The device is equipped with a resettable hour meter to determine the test period
Manufacturer's price approx. €59,500
Financing through our bank is also possible.
komplett-konzept.leasingo.de
You will find further items – new and used – in our shop!
International shipping costs on request!
Oglas je bil avtomatsko preveden. Možne so napake pri prevodu.
The Prüfpuls setup is designed for long-duration insulation tests on test objects with capacitance up to 6 nF.
Inverter for High Voltage Test Transformer
· Internal sine wave generator: 50-200Hz.
· Pulse width modulation at 16-24kHz of the sine wave via full bridge.
· Inverter voltage adjustable 0-600V, Imax=2.6A, maximum power 1.3kW
· Pulse current limitation 110A (cut-off threshold)
Cgjdpfx Afou Egz Rsnop
Pulse Transformer – Control
· Control via full bridge
· Full bridge power supply adjustable 0-1000V, max. 1.3A
· Pulse current limitation 100A (cut-off threshold)
· Pulse width 20-120μs, nominal 94μs, adjustable
· 2 selectable series inductances 150μH, 300μH to adapt the pulse width or rise times to the load capacitance and voltage
· Pulse repetition frequency 0.1 – 2.5 kHz, adjustable
· Polarity: adjustable positive, negative or alternating depending on the polarity of the sine signal
· Cosine-shaped pulse at transformer output
Pulse Transformer Cascade
· Output transformers in 5-stage cascaded configuration
· Overall turns ratio selectable via taps as 1:7.7, 1:10 or 1:15
· Maximum output voltage 15kV at the following possible load capacitances: * 6nF with a pulse width of 73μs at a repetition frequency of 2.5kHz * 10nF with a pulse width of 103μs at a repetition frequency of 1.25kHz
· Voltage divider 1:1000 in parallel
· Overvoltage limitation at approx. 20-23 kV via parallel spark gaps
· Thermistor for overtemperature detection in the first transformer stage
· Earth-side current measurement socket 100 mV/A
Qgqsbmp2
Breakdown Detection, Testing
· If the maximum bridge currents for transformer controls or for the bridge power supplies are exceeded, the high voltage is switched off
· The device is equipped with a resettable hour meter to determine the test period
Manufacturer's price approx. €59,500
Financing through our bank is also possible.
komplett-konzept.leasingo.de
You will find further items – new and used – in our shop!
International shipping costs on request!
Oglas je bil avtomatsko preveden. Možne so napake pri prevodu.
Ponudnik
Opomba: Brezplačno se registrirajte ali prijavite, za dostop do vseh informacij.
Pošlji povpraševanje
Telefon & Faks
+49 2862 ... oglasi
Ti oglasi bi vas prav tako lahko zanimali.
Mali oglas
Soerendonk
897 km
Menjalnik / menjalnik
Flender / SiemensK2S-2,5
Flender / SiemensK2S-2,5
Mali oglas
Wiefelstede
932 km
Namizni primež 150 mm
Heuer FrontSpannweite 235 mm
Heuer FrontSpannweite 235 mm
Mali oglas
Nemčija
650 km
Transformatorska postaja
Kalchschmid3076
Kalchschmid3076
Mali oglas
Tönisvorst
849 km
Okvir 28427
mitlaufendSPH 150 mm
mitlaufendSPH 150 mm
Vaš oglas je bil uspešno izbrisan
Prišlo je do napake