Impulzni generator za test izolacijeGBS Elektronik
rev3 Isolationstests bis 6nF
Impulzni generator za test izolacije
GBS Elektronik
rev3 Isolationstests bis 6nF
VB plus DDV
3.780 €
Stanje
Rabljeno
Lokacija
Borken 

Podatki o stroju
- Oznaka stroja:
- Impulzni generator za test izolacije
- Proizvajalec:
- GBS Elektronik
- Stanje:
- skoraj kot novo (rabljeno)
Cena in lokacija
VB plus DDV
3.780 €
- Lokacija:
- Dunkerstrasse 29, 46325 Borken/Burlo, Deutschland

Pokliči
Podrobnosti ponudbe
- ID oglasa:
- A17569468
- Referenčna številka:
- 21007
- Posodobitev:
- nazadnje dne 13.02.2026
Opis
GBS Prüfpuls rev3 Pulse Generator for Long-Term Insulation Tests
The Prüfpuls setup is designed for long-duration insulation tests on test objects with capacitance up to 6 nF.
Inverter for High Voltage Test Transformer
· Internal sine wave generator: 50-200Hz.
· Pulse width modulation at 16-24kHz of the sine wave via full bridge.
· Inverter voltage adjustable 0-600V, Imax=2.6A, maximum power 1.3kW
· Pulse current limitation 110A (cut-off threshold)
Pulse Transformer – Control
· Control via full bridge
· Full bridge power supply adjustable 0-1000V, max. 1.3A
Pedpfou Egz Rsx Andogn
· Pulse current limitation 100A (cut-off threshold)
· Pulse width 20-120μs, nominal 94μs, adjustable
· 2 selectable series inductances 150μH, 300μH to adapt the pulse width or rise times to the load capacitance and voltage
· Pulse repetition frequency 0.1 – 2.5 kHz, adjustable
· Polarity: adjustable positive, negative or alternating depending on the polarity of the sine signal
· Cosine-shaped pulse at transformer output
Pulse Transformer Cascade
· Output transformers in 5-stage cascaded configuration
· Overall turns ratio selectable via taps as 1:7.7, 1:10 or 1:15
· Maximum output voltage 15kV at the following possible load capacitances: * 6nF with a pulse width of 73μs at a repetition frequency of 2.5kHz * 10nF with a pulse width of 103μs at a repetition frequency of 1.25kHz
· Voltage divider 1:1000 in parallel
· Overvoltage limitation at approx. 20-23 kV via parallel spark gaps
· Thermistor for overtemperature detection in the first transformer stage
· Earth-side current measurement socket 100 mV/A
Qgqsbmp2
Breakdown Detection, Testing
· If the maximum bridge currents for transformer controls or for the bridge power supplies are exceeded, the high voltage is switched off
· The device is equipped with a resettable hour meter to determine the test period
Manufacturer's price approx. €59,500
Financing through our bank is also possible.
komplett-konzept.leasingo.de
You will find further items – new and used – in our shop!
International shipping costs on request!
Oglas je bil avtomatsko preveden. Možne so napake pri prevodu.
The Prüfpuls setup is designed for long-duration insulation tests on test objects with capacitance up to 6 nF.
Inverter for High Voltage Test Transformer
· Internal sine wave generator: 50-200Hz.
· Pulse width modulation at 16-24kHz of the sine wave via full bridge.
· Inverter voltage adjustable 0-600V, Imax=2.6A, maximum power 1.3kW
· Pulse current limitation 110A (cut-off threshold)
Pulse Transformer – Control
· Control via full bridge
· Full bridge power supply adjustable 0-1000V, max. 1.3A
Pedpfou Egz Rsx Andogn
· Pulse current limitation 100A (cut-off threshold)
· Pulse width 20-120μs, nominal 94μs, adjustable
· 2 selectable series inductances 150μH, 300μH to adapt the pulse width or rise times to the load capacitance and voltage
· Pulse repetition frequency 0.1 – 2.5 kHz, adjustable
· Polarity: adjustable positive, negative or alternating depending on the polarity of the sine signal
· Cosine-shaped pulse at transformer output
Pulse Transformer Cascade
· Output transformers in 5-stage cascaded configuration
· Overall turns ratio selectable via taps as 1:7.7, 1:10 or 1:15
· Maximum output voltage 15kV at the following possible load capacitances: * 6nF with a pulse width of 73μs at a repetition frequency of 2.5kHz * 10nF with a pulse width of 103μs at a repetition frequency of 1.25kHz
· Voltage divider 1:1000 in parallel
· Overvoltage limitation at approx. 20-23 kV via parallel spark gaps
· Thermistor for overtemperature detection in the first transformer stage
· Earth-side current measurement socket 100 mV/A
Qgqsbmp2
Breakdown Detection, Testing
· If the maximum bridge currents for transformer controls or for the bridge power supplies are exceeded, the high voltage is switched off
· The device is equipped with a resettable hour meter to determine the test period
Manufacturer's price approx. €59,500
Financing through our bank is also possible.
komplett-konzept.leasingo.de
You will find further items – new and used – in our shop!
International shipping costs on request!
Oglas je bil avtomatsko preveden. Možne so napake pri prevodu.
Ponudnik
Opomba: Brezplačno se registrirajte ali prijavite, za dostop do vseh informacij.
Registriran od: 2008
560 Oglasi na spletu
Pošlji povpraševanje
Telefon & Faks
+49 2862 ... oglasi
Ti oglasi bi vas prav tako lahko zanimali.
Mali oglas
Soerendonk
897 km
Menjalnik / menjalnik
Flender / SiemensK2S-2,5
Flender / SiemensK2S-2,5
Mali oglas
Wiefelstede
932 km
Namizni primež 150 mm
Heuer FrontSpannweite 235 mm
Heuer FrontSpannweite 235 mm
Vaš oglas je bil uspešno izbrisan
Prišlo je do napake