Adapter za voltmeter za visoko napetostChilworth
JCI 164
Adapter za voltmeter za visoko napetost
Chilworth
JCI 164
Začetna cena brez DDV
1.600 €
Stanje
Rabljeno
Lokacija
Borken 

Prikaži slike
Prikaži karto
Podatki o stroju
- Opis stroja:
- Adapter za voltmeter za visoko napetost
- Proizvajalec:
- Chilworth
- Model:
- JCI 164
- Stanje:
- zelo dobro (rabljeno)
Cena in lokacija
Začetna cena brez DDV
1.600 €
- Lokacija:
- Dunkerstrasse 29, 46325 Borken/Burlo, DE
Klic
Prodaja strojev

Ste našli novo napravo? Zdaj staro pretvorite v denar.
Dosežite najboljšo ceno prek Machineseeker.
Več o prodaji strojev
Več o prodaji strojev
Podrobnosti ponudbe
- ID ponudbe:
- A17570008
- Št. reference:
- 21633
- Nazadnje posodobljeno:
- dne 06.08.2025
Opis
Chilworth JCI 164 High Voltage Adapter
General Description
The JCI 146 is a voltmeter adapter component designed for integration into broader experimental systems.
In combination with our JCI 140, this system enables measurement of live conductors with voltages up to ± 60 kV DC via direct connection, delivering accuracy of ± 2% (nominal) with minimal loading effects on the device under test.
The high input impedance and low capacitance of the JCI 146 allow for more accurate DC voltage measurements.
Other conventional techniques for direct high-voltage measurement (e.g., high-voltage meters, capacitive and resistive divider networks, etc.) often yield inaccurate results due to loading effects caused by the measurement setup.
This device can be used for cross-checking calibration and accuracy of high-voltage sources by power utilities, calibration test houses, and cable manufacturers, among other application areas.
Dkedpfxsu Ehh Ej Ag Nsu
Features
- Direct measurement of live conductors up to ± 60 kV DC
- High precision measurement with minimal loading effect
- Low input capacitance
- Very high input impedance, typically 10¹³ Ohms
- Can be integrated into a wide range of test measurement and research systems
- Optional battery-powered and optically isolated data acquisition module available for remote monitoring of high voltage
Specification
Measurement:
- Maximum measurable voltage: ± 60 kV DC
Input Impedance:
- No less than 4.7 × 10¹³ Ohms at ± 50 kV
Input Capacitance:
- 32 pF (± 20%) (JCI 146 chamber only)
Installation:
- Fixed installation (permanent earth connection required)
Usage:
- Used in Faraday cage environments (not standard supply)
Accuracy:
- Nominal ± 2%
Attenuation:
- 1/10 of the reading indicated on JCI 140
For use with the JCI 140 static monitor and JCI 165 data acquisition module.
Find more items – new and used – in our shop!
International shipping costs on request!
Oglas je bil preveden samodejno, zaradi česar je morda prišlo do napak pri prevodu.
General Description
The JCI 146 is a voltmeter adapter component designed for integration into broader experimental systems.
In combination with our JCI 140, this system enables measurement of live conductors with voltages up to ± 60 kV DC via direct connection, delivering accuracy of ± 2% (nominal) with minimal loading effects on the device under test.
The high input impedance and low capacitance of the JCI 146 allow for more accurate DC voltage measurements.
Other conventional techniques for direct high-voltage measurement (e.g., high-voltage meters, capacitive and resistive divider networks, etc.) often yield inaccurate results due to loading effects caused by the measurement setup.
This device can be used for cross-checking calibration and accuracy of high-voltage sources by power utilities, calibration test houses, and cable manufacturers, among other application areas.
Dkedpfxsu Ehh Ej Ag Nsu
Features
- Direct measurement of live conductors up to ± 60 kV DC
- High precision measurement with minimal loading effect
- Low input capacitance
- Very high input impedance, typically 10¹³ Ohms
- Can be integrated into a wide range of test measurement and research systems
- Optional battery-powered and optically isolated data acquisition module available for remote monitoring of high voltage
Specification
Measurement:
- Maximum measurable voltage: ± 60 kV DC
Input Impedance:
- No less than 4.7 × 10¹³ Ohms at ± 50 kV
Input Capacitance:
- 32 pF (± 20%) (JCI 146 chamber only)
Installation:
- Fixed installation (permanent earth connection required)
Usage:
- Used in Faraday cage environments (not standard supply)
Accuracy:
- Nominal ± 2%
Attenuation:
- 1/10 of the reading indicated on JCI 140
For use with the JCI 140 static monitor and JCI 165 data acquisition module.
Find more items – new and used – in our shop!
International shipping costs on request!
Oglas je bil preveden samodejno, zaradi česar je morda prišlo do napak pri prevodu.
Ponudnik
Opomba: Brezplačno se registrirajte ali prijavite, za dostop do vseh informacij.
Registriran od: 2008
Pošlji zahtevo
Telefon & Faks
+49 2862 ... oglasi
Vaš oglas je bil uspešno izbrisan
Prišlo je do napake