LECO C230 CARBON ANALYZER
Carbon Determination C230
The LECO C230 Carbon Analyzer is a microprocessor-based, software-controlled instrument for measuring the carbon and sulfur content in metals, ores, ceramics, and other inorganic materials. The C230 utilizes an induction furnace and measures carbon by infrared absorption.
The infrared (IR) source consists of a nichrome wire heated by resistance to 8500°C. The IR source emits visible energy as well as all wavelengths of the infrared spectrum. Carbon dioxide can be used for descriptive purposes; the same principle applies for sulfur detection. Carbon dioxide absorbs IR energy at a specific wavelength within the IR spectrum. Energy from the IR source is absorbed as the gas flows through the cell, thereby preventing it from reaching the IR detector.
An IR cell is used both for reference and for measurement. The total carbon, in the form of carbon dioxide, is continuously and simultaneously detected. The initial reference level or baseline for the detector is established by passing oxygen through the cell to purge residual atmospheric gases.
Technical Data:
Required Gases:
Carrier gas: Oxygen 99.5% pure, 40 psi
Pneumatic gas: Compressed air, nitrogen, or argon, 40 psi (2.76 bar), source must be oil- and water-free
Gas Flow (based on nominal analysis time):
Measurement: 3 liters per analysis
Pneumatic: 1 liter per analysis
Regulators:
Oxygen: 501-291 O₂ pressure regulator
Compressed air: 766-036 compressed air regulator
Inert gas: 764-216 inert gas regulator
Todpjxxaxuofx Abgsf
Furnace: Induction, 18 MHz, 2.2 kW
Data Transfer: Included
Data Storage:
Without PC: 10 sample weights, 50 responses, 5 methods
Without PC: Internal memory /optional external display
Without PC: Liquid crystal (16 x 26 characters)
Power Requirement:
Determinator: 230 V, ±10%, 50/60 Hz, single-phase, max. 15 amperes
Operating current: 12 A
Standby current: 4 A
Condition: used
Scope of delivery: (See image)
(Changes and errors in technical data, specifications reserved!)
Should you have further questions, we will be happy to answer them by phone.
Oglas je bil preveden samodejno, zaradi česar je morda prišlo do napak pri prevodu.
Carbon Determination C230
The LECO C230 Carbon Analyzer is a microprocessor-based, software-controlled instrument for measuring the carbon and sulfur content in metals, ores, ceramics, and other inorganic materials. The C230 utilizes an induction furnace and measures carbon by infrared absorption.
The infrared (IR) source consists of a nichrome wire heated by resistance to 8500°C. The IR source emits visible energy as well as all wavelengths of the infrared spectrum. Carbon dioxide can be used for descriptive purposes; the same principle applies for sulfur detection. Carbon dioxide absorbs IR energy at a specific wavelength within the IR spectrum. Energy from the IR source is absorbed as the gas flows through the cell, thereby preventing it from reaching the IR detector.
An IR cell is used both for reference and for measurement. The total carbon, in the form of carbon dioxide, is continuously and simultaneously detected. The initial reference level or baseline for the detector is established by passing oxygen through the cell to purge residual atmospheric gases.
Technical Data:
Required Gases:
Carrier gas: Oxygen 99.5% pure, 40 psi
Pneumatic gas: Compressed air, nitrogen, or argon, 40 psi (2.76 bar), source must be oil- and water-free
Gas Flow (based on nominal analysis time):
Measurement: 3 liters per analysis
Pneumatic: 1 liter per analysis
Regulators:
Oxygen: 501-291 O₂ pressure regulator
Compressed air: 766-036 compressed air regulator
Inert gas: 764-216 inert gas regulator
Todpjxxaxuofx Abgsf
Furnace: Induction, 18 MHz, 2.2 kW
Data Transfer: Included
Data Storage:
Without PC: 10 sample weights, 50 responses, 5 methods
Without PC: Internal memory /optional external display
Without PC: Liquid crystal (16 x 26 characters)
Power Requirement:
Determinator: 230 V, ±10%, 50/60 Hz, single-phase, max. 15 amperes
Operating current: 12 A
Standby current: 4 A
Condition: used
Scope of delivery: (See image)
(Changes and errors in technical data, specifications reserved!)
Should you have further questions, we will be happy to answer them by phone.